(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Please be informed that our office is closed during the upcoming Labour Day Holiday in 2024. We would also like to inform you that there may be a potential delay in response/shipment from the supplier due to the Japan Golden Week holiday which falls from 29th April to 6th May 2024. Click here for details.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

MELSEC-F Input/Output Expansion Block

MELSEC-F Input/Output Expansion Block

An input/output expansion block that can receive power supply from a basic power supply unit.
[Features]
· Can expand input by 16 points.
· Can be connected to the back of a basic unit or expansion unit.
[Applications]
· Convenient for expanding input/output, receiving power supply from a basic unit or expansion unit.

PDF

Variation

MELSEC-F input/output expansion block: related images

FX2N-16EX

MELSEC-F input/output expansion block: related images

FX2N-16EX-C

MELSEC-F input/output expansion block: related images

FX2N-16EYR

MELSEC-F input/output expansion block: related images

FX2N-16EYT

MELSEC-F input/output expansion block: related images

FX2N-16EYT-C

MELSEC-F input/output expansion block: related images

FX2N-8EX

MELSEC-F input/output expansion block: related images

FX2N-8EYR

MELSEC-F input/output expansion block: related images

FX2NC-16EX-T

General Specifications

Common

Ambient Temperature0 To 55°C - When operating -25 To 75°C - When saving
Relative Humidity5 To 95% RH (No Condensation) - When Operating
Vibration-resistantWhen Mounting To DIN RailFrequency: 10 To 57 HzSingle Amplitude: 0.035 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each)
Assessment Standards Are Based On IEC61131-2
Frequency: 57 To 150 HzAcceleration: 4.9 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each)
Assessment Standards Are Based On IEC61131-2
When Mounting DirectlyFrequency: 10 To 57 HzSingle Amplitude: 0.075 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each)
Assessment Standards Are Based On IEC61131-2
Frequency: 57 To 150 HzAcceleration: 9.8 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each)
Assessment Standards Are Based On IEC61131-2
Shock-Resistant147 m/s2, For A Half-sine Pulse Three Times In Directions X, Y, And Z For A Duration Of 11 ms. The Assessment Standards Are Based On IEC611131-2
Noise ResistantAchieved Through A Noise Simulator With A Noise Voltage Of 1,000 Vp-p, Noise Width Of 1 μs, Rise Time Of 1 ns, And Frequency Of 30 To 100 Hz
Voltage ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter
Circumstances Of UseWhen There Is Not A Large Amount Of Conductive Dust, And No Corrosion Or Flammable Gas
Frequency Of UseCannot Be Used In Pressurized Environments Below 2,000 m. Doing So May Cause Failures.

FX2N-16EX

Voltage ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter

FX2N-16EX-C

Voltage ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter

FX2N-16EYR

Voltage ResistanceBetween The Expansion Output Block Output Terminal And Earth Terminal: 1 Minute At 1,500 V AC
Insulation ResistanceBetween The Expansion Output Block Output Terminal (Relay) And Earth Terminal: 5 MΩOr More At 500 V DC On An Insulation Resistance Meter

FX2N-16EYT

Voltage ResistanceBetween The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter

FX2N-16EYT-C

Voltage ResistanceBetween The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter

FX2N-8EX

Voltage ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter

FX2N-8EYR

Voltage ResistanceBetween The Expansion Output Block Output Terminal And Earth Terminal: 1 Minute At 1,500 V AC
Insulation ResistanceBetween The Expansion Output Block Output Terminal (Relay) And Earth Terminal: 5 MΩOr More At 500 V DC On An Insulation Resistance Meter

FX2NC-16EX-T

Ambient Temperature0 To 55°C - When Operating -20 To 70°C - When Saving
Relative Humidity35 To 85% RH (No Condensation) - When Operating
Vibration-resistantWhen Mounting To DIN RailFrequency: 10 To 57 HzSingle Amplitude: 0.035 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each)
Assessment Standards Are Based On IEC61131-2
Frequency: 57 To 150 HzAcceleration: 4.9 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each)
Assessment Standards Are Based On IEC61131-2
Shock-Resistant147 m/s2, For A Half-sine Pulse Three Times In Directions X, Y, And Z For A Duration Of 11 ms.
The Assessment Standards Are Based On IEC611131-2
Noise ResistantAchieved Through A Noise Simulator With A Noise Voltage Of 1,000 Vp-p, Noise Width Of 1 μs, Rise Time Of 1 ns, And Frequency Of 30 To 100 Hz
Voltage ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter
Part Number
FX2N-8ER
FX2N-8EYR
FX2N-8EYR-S-ES/UL
FX2N-16EYR
FX2N-32ER
FX2N-48ER
FX2N-48ER-D
FX2N-48ER-UA1/UL
FX2NC-16EYR-T
FX5-8EYR/ES
FX5-16ER/ES
FX5-16EYR/ES
FX5-32ER/DS
FX5-32ER/ES
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber Of Inputs Rated Input Voltage
(V)
Number of Outputs Output Format Representative Standard Features Applicable sequencer Number Of Inputs
(Point)
Number of Outputs
(Point)
Terminal shape Type of unit Number of input channels
(ch)
Number of output channels
(ch)
Voltage input range
(V)
Current input range
(mA)
Voltage output range Current output range Type of unit Resistance Load
(A/1 Point)

SGD 163.10

1 Piece(s) 91 Day(s) 4DC24V4Relay contact output--FX3G / FX3GC / FX3U / FX3UC44--------Input/output-

SGD 163.10

1 Piece(s) 91 Day(s) NA(Not applicable)8Relay contact output--FX1N / FX1NC / FX2N / FX2NC / FX3G / FX3GC / FX3U / FX3UCNA8Vertical Type Terminal BlockOutput-------2 A/1 piece

-

1 Piece(s) Quote NANot available8Relay contact outputCE / UL / CUL-FX3G / FX3GC / FX3UCNA8--------Output-

SGD 259.10

1 Piece(s) 91 Day(s) NA(Not applicable)16Relay contact output--FX1N / FX1NC / FX2N / FX2NC / FX3G / FX3GC / FX3U / FX3UCNA16Vertical Type Terminal BlockOutput--------

SGD 511.60

1 Piece(s) 91 Day(s) 16DC24V16Relay contact output--FX3G / FX3U1616--------Input/output-

SGD 700.10

1 Piece(s) 91 Day(s) 24DC24V24Relay contact output--FX3G / FX3U2424--------Input/output-

SGD 669.80

1 Piece(s) 91 Day(s) 24DC24V24Relay contact output--FX3G / FX3U2424--------Input/output-

SGD 637.90

1 Piece(s) 91 Day(s) 24AC100V24Relay contact outputCE / UL / CUL-FX3G / FX3U2424----------

SGD 335.70

1 Piece(s) 91 Day(s) NA(Not applicable)16Relay contact outputCE / UL / CUL-FX3GC / FX3UCNA16--------Output-

SGD 138.80

1 Piece(s) 91 Day(s) NA(Not applicable)-Relay contact outputCE / UL / CUL-FX5U / FX5UCNA8Terminal block-------Output-

SGD 246.40

1 Piece(s) 91 Day(s) 8DC24V8Relay contact outputCE / UL / CUL-FX5U / FX5UC88Terminal block-------Input / output-

SGD 194.30

1 Piece(s) 91 Day(s) NA(Not applicable)-Relay contact outputCE / UL / CUL-FX5U / FX5UCNA16Terminal block-------Output-

SGD 345.30

1 Piece(s) 91 Day(s) 16DC24V0Relay contact outputCE / UL / CULBuilt-in DC power supplyFX5U / FX5UC1616Terminal block-------Input / output-

SGD 437.30

1 Piece(s) 91 Day(s) -DC24V-Relay contact outputCE / UL / CULBuilt-in AC power supplyFX5U1616Terminal block-------Input/output-

Loading...

  1. 1
 

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)