(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Please be informed that our office is closed during the upcoming Labour Day Holiday in 2024. We would also like to inform you that there may be a potential delay in response/shipment from the supplier due to the Japan Golden Week holiday which falls from 29th April to 6th May 2024. Click here for details.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

Moisture Control Tube, Series IDK

Moisture Control Tube, Series IDK

[Features]
· Prevents condensation in small cylinders and air grippers.
· Draws out internal water vapor.
· No power supply or additional engineering required.
· Just install the Moisture Control Tube into your existing setup and go.

(i)Caution

  • Refer to the catalog for product specifications.
  • Product images may be representative images. Refer to the catalog for details.

PDF

Part Number

Configured Part Number is shown.

Moisture Control Tube IDK Series Specifications

Straight type

IDK Series (Straight Type) external appearance

IDK Series (Straight Type) external appearance

Inner sleeve external appearance

Inner sleeve external appearance

ModelIDK02IDK04IDK06
Fluid*1Compressed air
Maximum operating pressure0.7 MPa
Operating temperature0 to 60°C (no freezing)
Operating environment*2)Indoors where there is no exposure to water, etc. (0 to 40°C, 0 to 75% RH)
Minimum bending radius*3) mm102040
Number of moisture control
tubes
2 pcs
ColorTransparent [Color will turn to brown over time but the functions are not affected. ]
Applicable fittings*4)KQ2
MaterialFluoropolymer

*1: Use the moisture control tube with a refrigerated air dryer and a mist separator installed in the upstream compressed air line. The condensation prevention performance may be lowered depending on the quality of the compressed air (oil, dewpoint) supplied.
*2: Use the product in an operating environment where humidity is low. The condensation prevention performance may be lowered if used under a high-humidity environment.
*3: Minimum bending radius is the value at which the moisture control tube is bent or flattened at 20°C. During actual use, be careful not to bend or flatten, etc., the tube or the inner sleeve.
*4: The inner sleeve is already mounted and cannot be removed. If the inner sleeve comes off, re-insert the sleeve before mounting the fitting.
*5: Do not cut the tube.

Drawings

Straight Type dimensional drawing

Straight Type dimensional drawing

 

(Units: mm)

 

ModelOuter diameter × inner diameter
D
Nominal length
X
Full length
L
IDK02-1002 × 1.2100120
IDK02-200200220
IDK04-1004 × 2.5100140
IDK04-200200240
IDK06-1006 × 4100140
IDK06-200200240

*Dimensions at 40% relative humidity. Dimensions may change if the relative humidity changes.

Coil Shape Type

IDK Series (Coil Shape Type) external appearance

IDK Series (Coil Shape Type) external appearance

ModelIDK04-□-C1IDK06-□-C1
Fluid*1Compressed air
Maximum operating pressure0.7 MPa
Fluid temperature0 to 60°C (no freezing)
Operating environment*2Indoors where product is not exposed to water, etc. (0 to 40°C, 0 to 75% RH)
Number of moisture control tubes2 pcs
ColorTransparent [Color will turn to brown over time,
but the functions are not affected. ]
Applicable fittings*3)KQ2
MaterialFluoropolymer

*1: Use the moisture control tube with a refrigerated air dryer and a mist separator installed in the upstream compressed air line. The condensation prevention performance may be lowered depending on the quality of the compressed air (oil, dewpoint) supplied.
*2: Use the product in an operating environment where humidity is low. The condensation prevention performance may be lowered if used under a high-humidity environment.
*3: The inner sleeve is already mounted and cannot be removed. If the inner sleeve comes off, re-insert the sleeve before mounting the fitting.

Drawing (Per Tube)

 

(Units: mm)

 

IDK04-100-C1 dimensional drawing

IDK04-100-C1 dimensional drawing

 

(Units: mm)

 

IDK04-200-C1 dimensional drawing

IDK04-200-C1 dimensional drawing

 

(Units: mm)

 

Part B details

Part B details

 

(Units: mm)

 

IDK06-100-C1 dimensional drawing

IDK06-100-C1 dimensional drawing

 

(Units: mm)

 

IDK06-200-C1 dimensional drawing

IDK06-200-C1 dimensional drawing

  • *Due to the material, the above dimensions may vary depending on the environment (temperature and humidity), including expansion of Part A.
  • *The images are representative models. The appearance may differ from the actual product.
Part Number
IDK02-100
IDK02-200
IDK04-100
IDK04-100-C1
IDK04-200
IDK04-200-C1
IDK06-100
IDK06-100-C1
IDK06-200
IDK06-200-C1
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Outer Dia. D
(Ø)
O.D. [Distinction] Inner Dia. d
(Ø)
I.D. [Distinction] Number of Cables
(Core)
Minimum Bending Radius
(mm)
Operating Temperature
(°C)
Operating Pressure Range (when using air)
(MPa)
Length
(m)

SGD 50.40

1 Piece(s) 46 Day(s) Straight-~2-~2-10--0.1

SGD 63.70

1 Piece(s) 46 Day(s) Straight-~2-~2-10--0.2

SGD 71.63

1 Piece(s) 46 Day(s) Straight4~42.5~3-20--0.1

SGD 94.97

1 Piece(s) 46 Day(s) Coil4~42.5~31-0~60null~0.70.1

SGD 95.55

1 Piece(s) 46 Day(s) Straight4~42.5~3-20--0.2

SGD 127.40

1 Piece(s) 46 Day(s) Coil4~42.5~31-0~60null~0.70.2

SGD 92.87

1 Piece(s) 46 Day(s) Straight6~64~41400~60null~0.70.1

SGD 124.72

1 Piece(s) 46 Day(s) Coil6~64~41-0~60null~0.70.1

SGD 130.08

1 Piece(s) 46 Day(s) Straight6~64~4-40--0.2

SGD 172.55

1 Piece(s) 46 Day(s) Coil6~64~41-0~60null~0.70.2

Loading...

  1. 1

Basic Information

Cutting Service Usage Presence Material Fluororesin Applicable Fluid Air
Operating Environment Standard Color Transparency Material, Fluororesin Standard Fluoropolymer

Tech Support