(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Please be informed that our operating hours are from 9:00~15:00 during the upcoming Hari Raya Haji Holiday 2024. Click here for details.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

3‑Port Direct Operated Solenoid Valve - Metal Seal VS3135/3145 Series

3‑Port Direct Operated Solenoid Valve - Metal Seal VS3135/3145 Series

The main valve structure is a metal seal type solenoid valve.
[Features]
・ Direct acting solenoid valve
・ Pressure can be used from 0 MPa
・ Different pressures can be supplied
・ Manifold model: VVS310, VVS311
・ Body size: 3/8 standard (VS3135), 1/2 standard (VS3145)
・ Screw type: Rc, NPT, NPTF, G
・ Option: None, manual (Locking type)

(i)Caution

  • Product images may be representative. Refer to the manufacturer's catalog for details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

3-Port Solenoid Valve, Direct Operated Type, VS3135/VS3145 Series, Metal Seal Specifications

VS3135/VS3145 Series terminal type external appearance

VS3135/VS3145 Series terminal type external appearance

VS3135/VS3145 Series external appearance

VS3135/VS3145 Series external appearance

VS3135/VS3145 Series JIS symbol

VS3135/VS3145 Series JIS symbol

FluidAir, inert gases
Operating Pressure1.5 MPa
Guaranteed Proof Pressure0 to 1.0 MPa
*1: Ambient Temperature and Operating Fluid Temperature °C-20 to 60
*2: LubricationNot required
Manual OperationNon-locking type available (manual is optional)
Electrical EntryGrommet, terminal conduit
Drip-proof terminal conduit
Coil Rated VoltageAC100, 200 V 50/60 Hz
DC24 V
Allowable Voltage Fluctuation-15% to 10% of rated voltage
Coil Insulation Type*3: Class B or equivalent (130°C)
Impact Resistance / Vibration Resistance: m/s2*4: 150/50

*1: In low temperatures, dry air is required. (no freezing)
*2: If lubricating, use turbine oil class 1 (ISO VG32).
*3: Based on JIS C 4003.
*4: Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunctions occurred in a 1-sweep test between 45 and 2,000 Hz. The test was performed in both energized and non-energized states and in the axial direction and at right angles to the main valve and armature. (Initial value)

Model

ModelVS3135VS3145
Flow Rate Characteristics P → AA → EP → AA → E
C (dm3 (s·bar)]bCvC (dm3 (s·bar)]bCvC (dm3 (s·bar)]bCvC (dm3 (s·bar)]bCv
1/46.10.31.56.10.41.6------
3/87.20.21.87.30.21.8------
1/29.00.22.39.00.32.4180.274.8160.344.1
3/4------200.215.1150.464.5
*1: Response Time msAC30 or less30 or less
DC60 or less80 or less
*2: Maximum Operating Frequency CPMAC300 or less180 or less
DC180 or less180 or less
Weight kgAC0.81.6
DC1.12.4
Apparent Power VAACStarting50 HZ100300
60 HZ90360
Holding50 HZ2050
60 HZ1460
Power Consumption WDC13.224

*1: Based on JIS B 8375-1981. At 0.5 MPa with no surge voltage suppressor.
*2: The minimum operating frequency is according to JIS B 8375 (once per 30 days).
*3: *1 and *2 assume controlled clean air.

Structural Drawing

VS3135/VS3145 Series structural drawing

VS3135/VS3145 Series structural drawing

NumberPart nameMaterial
1BodyDie-cast aluminum
2Solenoid CoverDie-cast aluminum
3Spool/SleeveStainless steel
4CapResin
5BushingResin
6SpringSteel wire
7Rubber Plug for CordNBR
8Round Head Combination ScrewSteel wire
9Plug for CoverNBR
10GasketNBR

11. Solenoid Coil Assembly

Electrical EntryVoltage
Grommet100 V AC
200 V AC
24 V DC
Terminal conduit100 V AC
200 V AC
24 V DC

Outline dimensional drawing

VS3135/VS3145 dimensional drawing

VS3135/VS3145 dimensional drawing

 

(Unit: mm)

 

ModelPiping Connection Port Diameter RcABCDEFGHJKLMNPøQTerminal-Related Dimensions
RSTU
VS3135-02
VS3135-03
VS3135-04
1/4, 3/8, 1/264646570113635964541932505076012096118
VS3145-04
VS3145-06
1/2, 3/4826888921181531281703536665296614096133
DC type dimensional drawing

DC type dimensional drawing

ModelPiping Connection Port Diameter RcABøC
VS3135-02
VS3135-03
VS3135-04
1/4 / 3/8 / 1/21296450.8
VS3145-04
VS3145-06
1/2, 3/41966860.5

Precautions

  • *Before use, be sure to read the safety precautions and common precautions sections in the SMC catalog.
  • *See the SMC catalog for information other than the above.
Part Number
VS3135-021
VS3135-021-N
VS3135-021-T
VS3135-021P
VS3135-021P-N
VS3135-021T
VS3135-021TL
VS3135-021TL-N
VS3135-021TLP
VS3135-021TLZ
VS3135-021TLZP
VS3135-021TP
VS3135-021TP-N
VS3135-021TZ
VS3135-021TZP
VS3135-021WT
VS3135-021WTB
VS3135-021WTB-N
VS3135-021WTBL-N
VS3135-021WTBP
VS3135-021WTL
VS3135-021WTLP
VS3135-021WTLZ
VS3135-021WTP
VS3135-031
VS3135-031-N
VS3135-031-T
VS3135-031P
VS3135-031P-N
VS3135-031T
VS3135-031T-F
VS3135-031T-N
VS3135-031TL
VS3135-031TL-N
VS3135-031TLP
VS3135-031TLZ
VS3135-031TLZP
VS3135-031TP
VS3135-031TP-F
VS3135-031TP-N
VS3135-031TZ
VS3135-031TZ-N
VS3135-031TZP
VS3135-031WT
VS3135-031WTB
VS3135-031WTBL
VS3135-031WTBLZ
VS3135-031WTBP
VS3135-031WTBZ
VS3135-031WTL
VS3135-031WTLP
VS3135-031WTLZ
VS3135-031WTZ
VS3135-041
VS3135-041-N
VS3135-041-T
VS3135-041P
VS3135-041P-N
VS3135-041P-T
VS3135-041T
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipSpecifications Voltage Pipe Port Type Plumbing Thread Nominal CV Value Lead wire electrical entry Indicator light / Surge voltage suppressor Option Body size

SGD 235.32

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/41.5Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPTF1/41.5Grommet-None3/8 standard

SGD 251.53

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/41.5Grommet-Manual (lock type)3/8 standard

SGD 271.72

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduit-None3/8 standard

SGD 301.12

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/41.5Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduitWith lamp and surge voltage suppressor (With AXT307-1-□)Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/41.5Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

SGD 297.85

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Drip-proof terminal conduit-None3/8 standard

SGD 326.43

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/41.5Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/41.5Drip-proof conduit terminal (through hole metallic fittings used), with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Drip-proof conduit terminal (through hole metallic fittings used)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Dripproof conduit terminal with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Dripproof conduit terminal with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Dripproof conduit terminal with indicator light/surge voltage suppressor (With AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Drip-proof terminal conduit-Manual (lock type)3/8 standard

SGD 235.32

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Grommet-None3/8 standard

SGD 235.32

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100VNPT3/81.8Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPTF3/81.8Grommet-None3/8 standard

SGD 251.53

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT3/81.8Grommet-Manual (lock type)3/8 standard

SGD 271.72

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VG3/81.8Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT3/81.8Terminal conduit-None3/8 standard

SGD 301.12

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT3/81.8Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Lubrication FreeAC100VG3/81.8Terminal conduitNoneManual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT3/81.8Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

SGD 297.85

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Drip-proof terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Drip-Proof / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used)With lightNone3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used), with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used), with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Dripproof conduit terminal with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Dripproof conduit terminal with light-Manual (lock type)3/8 standard

SGD 365.63

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Dripproof conduit terminal with indicator light/surge voltage suppressor (With AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Dripproof conduit terminal with surge voltage suppressor (With AXT307-1-□)-None3/8 standard

SGD 235.32

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/22.3Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/22.3Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPTF1/22.3Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/22.3Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/22.3Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Lubrication FreeAC100VNPTF1/22.3GrommetNoneManual (lock type)3/8 standard

SGD 271.72

1 Piece(s) 46 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/22.3Terminal conduit-None3/8 standard

Loading...

Basic Information

Type Solenoid Valves Application Single Use Number of Ports 3-Port Valve
Mounting Orientation Direct Number of Solenoids Single Switching Type 2-Position Normally Closed
Status at Power Off Self-Recovery (Spring Return) Plumbing Direct Plumbing Driving Type Linear Motion Spool
Seal Type Standard Pressure Rating(MPa) 0 to 1.0

Tech Support