(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Please be informed that our operating hours are from 9:00~15:00 during the upcoming Hari Raya Haji Holiday 2024. Click here for details.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

Compact Vacuum Regulator ITV0090/0091 Series

Compact Vacuum Regulator ITV0090/0091 Series

Vacuum regulator with built-in one-touch tube fittings.
[Features]
· Stepless control of air pressure proportional to an electrical signal.
· ITV1000, 2000 and 3000 Series are compatible with various input specifications including serial communications.
· Compact and lightweight (integrated communications).
· Straight and right angle types available.
· With error indication LED.
· Flat bracket and L-bracket types available.

(i)Caution

  • Refer to the manufacturer's catalog for specifications and material details.
  • The product images may be representative images only. Refer to the manufacturer's catalog for shape details.

PDF

Compact Vacuum Regulator ITV009□ Series Specifications

Compact Vacuum Regulator ITV009□ Series external appearance

Compact Vacuum Regulator ITV009□ Series external appearance

Specifications

ModelITV009□
Minimum Supply PressureSet pressure -1 kPa
Maximum Supply Pressure-101 kPa
Set Pressure Range-1 to -100 kPa
Power SupplyVoltage24 V DC ±10%, 12 to 15 V DC
Current ConsumptionPower supply voltage 24 V DC type: 0.12 A or less
Power supply voltage 12 to 15 V DC type: 0.18 A or less
Input SignalVoltage Type0 to 5 V DC, 0 to 10 V DC
Current Type4 to 20 mA DC, 0 to 20 mA DC (sink type)
Input ImpedanceVoltage TypeApprox. 10 k Ω
Current TypeApprox. 250 Ω
Output Signal Note 4:Analog Output1 to 5 V DC (output impedance: approx. 1 kΩ)
Output accuracy ±6% F.S. or less
Linearity±1% F.S. or less
Hysteresis0.5% F.S. or less
Repeatability±0.5% F.S. or less
Sensitivity0.2% F.S. or less
Temperature Characteristics±0.12% F.S. / °C or less
Operating Temperature Range0 to 50°C (no condensation)
EnclosureIP65 equivalent *
Connection TypeBuilt-in one-touch fittings
Connection SizeFor Single UnitMetric Size[1], [2], [3]: ø4 mm
Inch Size[1], [2], [3]: ø5/32"
ManifoldMetric Size[1], [3]: ø6 mm, [2]: ø4 mm
Inch Size[1], [3]: ø1/4", [2]: ø5/32"
Weight Note 1:100 g or less (without options)

Note 1: Indicates the weight of a single unit.
For IITV00-n,
Total weight (g) ≤ number of stations (n) × 100 + 130 (weight of end block A and B assemblies) + DIN rail weight (g).
Note 2: When there is a downstream flow consumption, the pressure may become unstable depending on the tubing conditions.
Note 3: While the power is on, the solenoid valve may make noise when operating. This noise is normal and does not indicate a fault.
Note 4: When measuring ITV analog output from 1 to 5 V DC, if the load impedance is less than 100 kΩ, the analog monitor output accuracy of ±6% F.S. or less may not be achievable. If an accuracy within ±6% is required, contact the manufacturer for further assistance. Output pressure remains unaffected.
*When using under conditions equivalent to IP65, connect the fitting or tube to the breathing hole prior to use.
 (Refer to the manufacturer's catalog for details.)

Operating Principles

When the input signal rises, the vacuum pressure solenoid valve (1) turns ON. Due to this, part of the vacuum pressure (VAC.) supply passes through the vacuum pressure solenoid valve (1) and becomes vacuum pressure. This vacuum pressure feeds back to the control circuit (4) via the pressure sensor (3). Here, pressure corrections continue through alternate operation of the vacuum pressure solenoid valve and atmospheric pressure solenoid valve until the vacuum pressure becomes proportional to the input signal, thus supplying vacuum pressure that is consistently proportional to the input signal.

 
Operating principle drawing

Operating principle drawing

Block diagram

Block diagram

Drawing

 

(Unit: mm)

 

Single unit dimensional drawing 1

Single unit dimensional drawing 1

Single unit dimensional drawing 2

Single unit dimensional drawing 2

Single unit dimensional drawing 3

Single unit dimensional drawing 3

Single unit dimensional drawing 4

Single unit dimensional drawing 4

Port Positions

No.[1][2][3]
ITV009□VACOUTATM

Note: When using under conditions equivalent to IP65, connect the fitting or tube to the breathing hole prior to use. (Refer to the manufacturer's catalog for details.)

Single unit for manifold dimensional drawing

Single unit for manifold dimensional drawing

  • When using under conditions equivalent to IP65, connect the fitting or tube to the breathing hole prior to use. (Refer to the manufacturer's catalog for details.)
  • *Refer to the manufacturer's catalog for cable connector dimensions.

Linearity, Hysteresis

Linearity and hysteresis graph

Linearity and hysteresis graph

Repeatability

Repeatability graph (at 50% of signal input)

Repeatability graph (at 50% of signal input)

Notes

  • *Refer to the manufacturer's catalog for product information not detailed above.
  • *Product images are representative images only.
Part Number
ITV0090-0ML
ITV0090-0MN
ITV0090-0MS
ITV0090-1ML
ITV0090-2ML
ITV0090-2MS
ITV0090-3ML
ITV0090-3MN
ITV0090-3MS
ITV0091-2MS
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipSupply Side, Connecting Tube Diameter Control Side, Connecting Tube Diameter Input Signal Piping specifications Cable connector Bracket Power supply voltage

SGD 460.48

1 Piece(s) 46 Day(s) Ø4Ø6DC 4-20mAFor manifoldsRight angle type 2 mWithout bracket24 V DC

SGD 427.23

1 Piece(s) 46 Day(s) Ø4Ø6DC 4-20mAFor manifoldsWithout cable connectorWithout bracket24 V DC

SGD 460.48

1 Piece(s) 46 Day(s) Ø4Ø6DC 4-20mAFor manifoldsStraight type 3 mWithout bracket24 V DC

SGD 460.48

1 Piece(s) 46 Day(s) Ø4Ø6DC 0-20mAFor manifoldsRight angle type 2 mWithout bracket24 V DC

SGD 460.48

1 Piece(s) 46 Day(s) Ø4Ø6DC 0-5VFor manifoldsRight angle type 2 mWithout bracket24 V DC

SGD 460.48

1 Piece(s) 46 Day(s) Ø4Ø6DC 0-5VFor manifoldsStraight type 3 mWithout bracket24 V DC

SGD 460.48

1 Piece(s) 46 Day(s) Ø4Ø6DC 0-10VFor manifoldsRight angle type 2 mWithout bracket24 V DC

SGD 427.23

1 Piece(s) 46 Day(s) Ø4Ø6DC 0-10VFor manifoldsWithout cable connectorWithout bracket24 V DC

SGD 460.48

1 Piece(s) 46 Day(s) Ø4Ø6DC 0-10VFor manifoldsStraight type 3 mWithout bracket24 V DC

SGD 460.48

1 Piece(s) 46 Day(s) Ø4Ø6DC 0-5VFor manifoldsStraight type 3 mWithout bracket12 to 15 V DC

Loading...

  1. 1

Basic Information

Type Electronic Electropneumatic Regulator Control Method Internal Pilot Shape Standard
Supply Side, Connection Type One-Touch Plumbing Control Side, Connection Type One-Touch Plumbing Set Pressure Range(kPa) -1::-100

Tech Support