  • Please be informed that our office is closed during the upcoming Labour Day Holiday in 2024. We would also like to inform you that there may be a potential delay in response/shipment from the supplier due to the Japan Golden Week holiday which falls from 29th April to 6th May 2024. Click here for details.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

Electronic Temperature Controller E5C2 (E5C2-R20K AC100-240 0-1000)

Electronic Temperature Controller E5C2 E5C2-R20K AC100-240 0-1000

[Features]
· The smallest type, available at low cost
· Proportional (P) motion is available in the adjustment mode. In addition, reset adjustment function has been added
· The mounting adapter enables continuous close-contact installation
· Plug-in method enables DIN rail mounting and panel embedding

PDF

Japanese Only

Part Number

Configured Part Number is shown.

E5C2-R20K AC100-240 0-1000

Drawing

Drawing of electronic temperature controller
Electronic temperature controller

Terminal arrangement

Product Specifications

Rating

Power supply voltage100 to 240 V AC 50/60 Hz
Allowable voltage fluctuation range90 to 110% of power supply voltage
Power ConsumptionApprox. 3.6 VA
InputThermocouple (with burnout circuit)
Platinum Resistance Thermometer
Element compatible thermistor
Control methodON/OFF operation, proportional operation (P)
Setting methodAnalog setting
Indication systemNo indications
Control OutputRelay output1c 250 V AC 3 A (resistant load)
(However, the opening and closing capacity is 330 V A)
Ambient operating temperature-10 to +55℃ (however, no freezing or no condensation)
Operating ambient humidityRelative humidity 45 to 85%

*. Do not use the output of the inverter as a power supply.

Performance

Setting accuracy±2% FS or less (effect of electromagnetic interference ±4% FS or less)
Adjustment sensitivity0.5% FS or less (fixed)
Proportional band3%FS (fixed)
Proportional periodApprox. 20 s
Reset range5±1%FS * 2
Insulation Resistance20 MΩ or more (at 500 V DC megger)
Withstand Voltage2,000 V AC 50/60 Hz for 1 min
(however, between the conductive terminal batch and the non-charged metal part)
VibrationMalfunction10 to 55 Hz Single amplitude 0.15 mm X, Y, Z 10 min in each direction
Durability16.7 Hz Single amplitude 2 mm X, Y, Z 2 h in each direction
ImpactMalfunction147 m/s^2, 6 directions, 3 times each
Durability294 m/s^2, 6 directions, 3 times each
LifeElectrical100,000 times or more (110 V AC 3 A resistant load)
WeightApprox. 100 g (With recessed mounting adapter)
Protective EnclosureIEC standard, front operation unit IP40, terminal unit IP00
Applicable socketType P2CF-08 (sold separately), type P3G-08 (Sold separately)
Applicable front coverShape Y92A-48B (Sold separately)

* 2. The ON/OFF operation type does not have a reset function.
       The reset function is used to correct the offset during proportional operation.
       If the offset occurs below the set value, turn the reset adjustment axis to the right (clockwise).

Part Number
E5C2-R20K AC100-240 0-1000
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipInput Method Control Method Number of Control Points Number of Input Points
(pcs.)
Control Output 1 Standard scale
(℃)

SGD 157.80

1 Piece(s) 7 Day(s) or more ThermocoupleON/OFF Control11Relay0-1000