(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Please be informed that our office is closed during the upcoming Labour Day Holiday in 2024. We would also like to inform you that there may be a potential delay in response/shipment from the supplier due to the Japan Golden Week holiday which falls from 29th April to 6th May 2024. Click here for details.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

Chemical Liquid Valve Non-Metallic Exterior, Air Operated, Insert Bushing Type Fitting Integrated, Space Saving

Chemical Liquid Valve Non-Metallic Exterior, Air Operated, Insert Bushing Type Fitting Integrated, Space Saving

A integrated/space-saving insert bushing type connector for chemicals, with non-metal exterior that prevents liquid pooling.
[Features]
· A non-metal construction that joins the actuator to the body without using any metal screws.
· Special structure allows the valve to open and close slowly, preventing the formation of micro-bubbles.
· Can be used with liquid chemicals such as acids, alkalis and ultrapure water.
· Prevents seat surface misalignment and internal leakage.
· Prevents heavy impact to the valve and the generation of particles.
· Prevents diaphragm deformation and damage due to back pressure.

(i)Caution

  • Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.
  • Refer to the manufacturer's catalog for specification and material details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

PDF

Part Number

Configured Part Number is shown.

Chemical Valve With Non-Metallic Exterior, Insert Bushing Type Fitting, Integrated/Space-Saving Connector, LVQS Series Details

Chemical Valve With Non-Metallic Exterior, Insert Bushing Type Fitting, Integrated/Space-Saving Connector, LVQS Series product image

Chemical Valve With Non-Metallic Exterior, Insert Bushing Type Fitting, Integrated/Space-Saving Connector, LVQS Series product image

Chemical Valve With Non-Metallic Exterior, Insert Bushing Type Fitting, Integrated/Space-Saving Connector, LVQS Series Specifications

ModelLVQ20SLVQ30SLVQ40S
Connection Fitting Size234
Fitting typeIn/out portLQ1 or LQ2
Pilot PortLQ1
Orifice Diameterø4 (orifice diameter: 4 mm)ø8 (orifice diameter 8 mm)ø10 (orifice diameter: 10 mm)
Flow Rate CharacteristicsKv0.31.11.6
Cv0.351.31.9
Pressure Resistance (MPa)1
Pressure Used (Flow from A to B)Standard-98 kPa to +0.5 MPa*1
High Temperature-98 kPa to +0.3 MPa*1
Back Pressure (MPa)Standard0.3 or less
High Back Pressure0.42 or less
High Temperature0.3 or less
Valve Leakage Volume (cm³/min)0 (at water pressure)
Operating Pressure (MPa)0.3 to 0.5 (0.45 to 0.55 for high-back pressure specification)
Pilot Port Diameter1/8 in (ø3 [3 mm diameter]), ø4 (4 mm diameter), Rc 1/8, NPT 1/8
Fluid Temperature Used (°C)Standard0 to 100
High Temperature0 to 170
Ambient Temperature (°C)0 to 60
Weight (kg)0.0850.1750.223
  • *1 Cannot be used for vacuum retention. Please note that using the B Port side as a vacuum can shorten the product's lifespan.

Model Number Notation

Model number example

Model number example

(1) Body Class

NotationBody classOrifice Diameter
22ø4 (orifice diameter: 4 mm)
33ø8 (orifice diameter 8 mm)
44ø10 (orifice diameter 10 mm)

(2) Valve Type

0N.C.
1N.O.
2Double acting

(3) Body Type

SSpace-saving connector

(4) Fitting Type

NotationFitting typeBody class
VLQ12/3/4
SLQ22/3/4
  • *Insert bushings fit all models.

(5) Compatible Fitting Size

NotationFitting SizeBody class
234
072--
113--
134--
  • *Please select an item that is the same size as the fitting on the valve side.

(6) Pilot Port Type

No notationLQ1 integrated fittingConnection Tube Size
1/8 in × 0.086 in (3 × 2)
MLQ1 integrated fittingConnection Tube Size
4 × 3
RScrew-inRc 1/8
NScrew-inNPT 1/8

(7) Pilot Port Direction

NotationDirection
No notation(1)

Pilot port piping direction

Pilot port piping direction

Pilot port piping direction

  • *Please do not change the direction of the pilot port

(8) Option 1

No notationNone
1With flow rate control
2With bypass
3With flow rate control and bypass
4With indicator
5High back pressure (0.42 MPa)
6With high back pressure and flow rate control
9With high back pressure and indicator
  • *Items in Option 1 cannot be combined with each other.

(9) Option 2

NotationCompatible OptionsNote
12345678924
No notation-
J---------For high temperatures
NFor ammonium hydroxide
  • *Items in Option 2 cannot be combined with each other.

Example Diagram

Basic type, N. C. type, diagram

Basic type, N. C. type, diagram

Component Parts

NumberPart NameMaterial
1ActuatorPVDF
2Body classPFA
3DiaphragmPTFE
4Insert bushingPFA
5NutPFA

Chemical Valve With Non-Metallic Exterior, Insert Bushing Type Fitting, Integrated/Space-Saving Connector, LVQS Series Example Dimensions

 

(Unit: mm)

 

Basic type, high back pressure, N.C. Valve dimensional drawing

Basic type, high back pressure, N.C. Valve dimensional drawing

LVQ□0S-□-V / LVQ□0S-□-S Dimensions Table (N.C. Valve)

ModelABCDEFGHJKLMNPQR
V□S□
LVQ20S-V07
LVQ20S-S07
25.54631.55833.656.512899221.837571531.32125.3
LVQ30S-V11
LVQ30S-S11
28.55734.56945.47716.51061123250672037.22531.2
LVQ40S-V13
LVQ40S-S13
28.55734.56945.482.52212012637.555.5672037.22531.2
  • *LVQ60 is "V" only.
Part Number
LVQ20S-V07M-1
LVQ20S-V07M-1-J
LVQ20S-V07M-J
LVQ50S-S19-1
LVQ50S-S19-4
LVQ50S-S19N-4
LVQ50S-S19R-1
LVQ50S-V19R-1
LVQ51S-V19M
LVQ60S-S25-5
LVQ60S-V25N-1
LVQ61S-V25N
LVQ61S-V25R
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipBody class Valve type Fitting type Compatible sizes Pilot port type Option (1) Option (2) Orifice diameter
(ø)

-

1 Piece(s) Quote 2N.C.LQ1Fitting: 2LQ1 integrated fitting, connection tube size 4 × 3With flow rate controlNone4

-

1 Piece(s) Quote 2N.C.LQ1Fitting: 2LQ1 integrated fitting, connection tube size 4 × 3With flow rate controlFor high temperatures4

-

1 Piece(s) Quote 2N.C.LQ1Fitting: 2LQ1 integrated fitting, connection tube size 4 × 3NoneFor high temperatures4

-

1 Piece(s) Quote 5N.C.LQ2Fitting: 5LQ1 fitting integrated / connection tube size 1/8 "× 0.086" (3 × 2)With flow rate controlNone16

-

1 Piece(s) Quote 5N.C.LQ2Fitting: 5LQ1 fitting integrated / connection tube size 1/8 "× 0.086" (3 × 2)With indicatorNone16

-

1 Piece(s) Quote 5N.C.LQ2Fitting: 5Screw-in / NPT 1/8With indicatorNone16

-

1 Piece(s) Quote 5N.C.LQ2Fitting: 5Screw-in / Rc1/8With flow rate controlNone16

-

1 Piece(s) Quote 5N.C.LQ1Fitting: 5Screw-in / Rc1/8With flow rate controlNone16

-

1 Piece(s) Quote 5N.O.LQ1Fitting: 5LQ1 integrated fitting, connection tube size 4 × 3NoneNone16

-

1 Piece(s) Quote 6N.C.LQ2Fitting: 6LQ1 fitting integrated / connection tube size 1/8 "× 0.086" (3 × 2)High back pressure (0.42 MPa)None22

-

1 Piece(s) Quote 6N.C.LQ1Fitting: 6Screw-in / NPT 1/8With flow rate controlNone22

-

1 Piece(s) Quote 6N.O.LQ1Fitting: 6Screw-in / NPT 1/8NoneNone22

-

1 Piece(s) Quote 6N.O.LQ1Fitting: 6Screw-in / Rc1/8NoneNone22

Loading...

  1. 1

Basic Information

Pilot port direction 1

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)