  • Please be informed that our office is closed during the upcoming Labour Day Holiday in 2024. We would also like to inform you that there may be a potential delay in response/shipment from the supplier due to the Japan Golden Week holiday which falls from 29th April to 6th May 2024. Click here for details.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

300 / 30 V UL Standard

300 / 30 V UL Standard

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

300 V/30 V, UL standard, coiled cord, sheath (outer coating) material: PVC, AWG size: 23

  • VW-1
  • ULAWM
  • Strand Wire

● Curled cable with small coil outer diameter.
● The coil length can be extended by around 5 times.
● A7 series can be used for DIN connectors and A6 series for mini DIN connectors.

* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* Color and softness may vary slightly due to manufacturer changes.

Electrical Appliance and Material Safety Law certificate has not been obtained.

ULAWM 2464
ULAWM 20013

PDF

Part Number

Configured Part Number is shown.

A705R

Specifications

300 / 30 V UL Standard:Related Image



Be sure to read the following precautions when you place an order.
For the latest information regarding standard unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
* Length in "m" is included in model numbers. Always specify quantity as number of units, not as meters.
* Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering (check the Specification Table for number of wire cores). 1P (1 PS) is "x 2-core".
* Allowable current is to be used only as a reference value and is not guaranteed.

More Information

Specifications
Model NumberAWG SizeNumber of CoresSpecified Length
(Coil Length)
Approx. (cm)
Coil DimensionWire PartRatingAllowable Current
(A)
Conductor Resistance
Ω / km (20 °C)
Approximate
Weight
g / Piece
Coil Outside Diameter (D)
Approx. (mm)
Lead Cable Length at Both Side of Coil
(ℓ) Approx. cm
Conductor Configuration
(Pc / mm)
Finished Outer Diameter
(mm)
A705R23
* (0.25mm2)
530.5 (1ft)19.130.5 (12inch)21/0.135.59300 V / 80°C
UL2464
468400
A707R730.5 (1ft)22.2230.5 (12inch)21/0.135.84368500
A705-2R561 (2ft)19.115.2 (6inch)21/0.135.59468700
A707-2R761 (2ft)22.2215.2 (6inch)21/0.135.843681000
A705-3R591 (3ft)19.115.2 (6inch)21/0.135.594681000
A707-3R791 (3ft)22.2215.2 (6inch)21/0.135.843681500
A65128 * (0.08 mm2)261 (2ft)12.715.2 (6inch)19/0.083.430V / 60°C
UL20013
1186100
A652461 (2ft)12.715.2 (6inch)19/0.083.81186200
  
* (~ mm2) is to be used only as an estimated section area. Refer to the comparison table on >>Click here for details.

300 / 30 V UL Standard:Related Image

Wire Core Identification Table
Number of Cores1234567
Insulator ColorBlackWhiteRedGreenOrangeBlueYellow
 
Current Reduction Factor
Ambient Temperature (°C)40455055606570
Current Reduction Factor0.880.820.750.670.580.420.35
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) A705R: Allowable current value when the ambient temperature is 40 °C 4 x 0.88 = 3.52 (A)
Part Number
A705R
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHS

SGD 132.58

1 Piece(s)Available 4 Day(s) or more 10

Loading...

  1. 1

Basic Information

Overall Length(m) 0.305 Conductor Cross Section(mm2) 0.25 AWG size(AWG) 23
Number Of Cores(Core) 5 Rated Voltage 300V Shield None
Representative Standard UL Sheath (outer coating) material PVC Insulation body materials Polyethylene type