(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Please be informed that our office is closed during the upcoming Labour Day Holiday in 2024. We would also like to inform you that there may be a potential delay in response/shipment from the supplier due to the Japan Golden Week holiday which falls from 29th April to 6th May 2024. Click here for details.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

NET Straight/Panel Mountable Connector Harness

NET Straight/Panel Mountable Connector Harness

Harness for UL/CSA Standard Supported Connector

  • UL
  • CSA
  • TUV
  • For Power Supply
  • For Signal
  • Connection between Boards
  • Solder
  • MISUMI Original
Connector Acquired Standards
TÜV Standard
DIN VDE0627
UL StandardUL1977
CSA StandardC22.2NO.182.3
● A body ground structure with a high level of safety is used.


· Straight plugs cannot be mated with one another. Use a panel mount receptacle or a cable for relays when setting up a relay.

Wiring and Wire Color Page
>>Click here
Component Page
>>Click here

PDF

Specifications

NET Straight/Panel Mountable Connector Harness:Related Image

Specified Length (m)~ 0.91 ~ 44.1 ~ 50
Tolerance+20mm+50mm+ 3% of Specified Length
* The tolerance of the specified length is as described above.

Connector TypeShape Specification TypeOutline Image Drawing (Unit: mm)ConnectorShell Type
(Shell Size - Number of Cores)
Cable TypeSpecified Length
(m)
NETC

Nanaboshi Electric Mfg.Co,Ltd.






S
(Straight Connector)
NET Straight/Panel Mountable Connector Harness:Related ImageP
Male
(Pin)







S
Female
(Socket)



A1
24-3
(2-core + Ground)


A2
24-4
(3-core + Ground)


A3
28-4
(3-core + Ground)


A4
28-8
(7-core + Ground)


A5
32-3
(2-core + Ground)


A6
32-4
(3-core + Ground)
NET Straight/Panel Mountable Connector Harness:Related Image
0.2

~

50


Can be specified by 0.1m
increments
SY
(Straight Connector
/ Y Terminal)
NET Straight/Panel Mountable Connector Harness:Related Image
ST
(Straight Connector
/ Mark Tube)
NET Straight/Panel Mountable Connector Harness:Related Image
AS
(Relay Connector)
NET Straight/Panel Mountable Connector Harness:Related Image
ASY
(Relay Connector
/ Y Terminal)
NET Straight/Panel Mountable Connector Harness:Related Image
AST
(Relay Connector
/ Mark Tube)
NET Straight/Panel Mountable Connector Harness:Related Image
R
(Panel Mount
Connector)

(Flange Type)
NET Straight/Panel Mountable Connector Harness:Related Image
RY
(Panel Mount
Connector / Y Terminal)

(Flange Type)
NET Straight/Panel Mountable Connector Harness:Related Image


RT
(Panel Mount
Connector / Mark Tube)

(Flange Type)
NET Straight/Panel Mountable Connector Harness:Related Image

More Information

NET Straight/Panel Mountable Connector Harness:Related Image

Electrical Properties
Shell Type
(Shell Size - Number of Cores)
ConnectorA Cable C Cable
Rated Current
(A or less)
Rated Voltage
(V or less)
Section AreaRated VoltageAllowable Current
A (30°C)
Section AreaRated VoltageAllowable Current
A (30°C)
A1 (24-3)202503.5mm2
(AWG12)
600V28AWG12
(3.5 mm2)
600V27
A2 (24-4)152.0mm2
(AWG14)
17AWG14
(2.0 mm2)
18
A3 (28-4)203.5mm2
(AWG12)
25AWG12
(3.5 mm2)
22
A4 (28-8)152.0mm2
(AWG14)
13AWG14
(2.0 mm2)
13
A5 (32-3)305.5mm2
(AWG10)
36AWG10
(5.5 mm2)
35
A6 (32-4)303230
* The values are reference values, not guaranteed values.

NET Straight/Panel Mountable Connector Harness:Related Image
Part Number
NETC-AS-P-A1-C-[0.2-50/0.1]
NETC-AS-P-A1-V-[0.2-50/0.1]
NETC-AS-P-A2-C-[0.2-50/0.1]
NETC-AS-P-A2-V-[0.2-50/0.1]
NETC-AS-P-A3-C-[0.2-50/0.1]
NETC-AS-P-A3-V-[0.2-50/0.1]
NETC-AS-P-A4-C-[0.2-50/0.1]
NETC-AS-P-A4-V-[0.2-50/0.1]
NETC-AS-P-A5-C-[0.2-50/0.1]
NETC-AS-P-A5-V-[0.2-50/0.1]
NETC-AS-P-A6-C-[0.2-50/0.1]
NETC-AS-P-A6-V-[0.2-50/0.1]
NETC-AS-S-A1-C-[0.2-50/0.1]
NETC-AS-S-A1-V-[0.2-50/0.1]
NETC-AS-S-A2-C-[0.2-50/0.1]
NETC-AS-S-A2-V-[0.2-50/0.1]
NETC-AS-S-A3-C-[0.2-50/0.1]
NETC-AS-S-A3-V-[0.2-50/0.1]
NETC-AS-S-A4-C-[0.2-50/0.1]
NETC-AS-S-A4-V-[0.2-50/0.1]
NETC-AS-S-A5-C-[0.2-50/0.1]
NETC-AS-S-A5-V-[0.2-50/0.1]
NETC-AS-S-A6-C-[0.2-50/0.1]
NETC-AS-S-A6-V-[0.2-50/0.1]
NETC-AST-P-A1-C-[0.2-50/0.1]
NETC-AST-P-A1-V-[0.2-50/0.1]
NETC-AST-P-A2-C-[0.2-50/0.1]
NETC-AST-P-A2-V-[0.2-50/0.1]
NETC-AST-P-A3-C-[0.2-50/0.1]
NETC-AST-P-A3-V-[0.2-50/0.1]
NETC-AST-P-A4-C-[0.2-50/0.1]
NETC-AST-P-A4-V-[0.2-50/0.1]
NETC-AST-P-A5-C-[0.2-50/0.1]
NETC-AST-P-A5-V-[0.2-50/0.1]
NETC-AST-P-A6-C-[0.2-50/0.1]
NETC-AST-P-A6-V-[0.2-50/0.1]
NETC-AST-S-A1-C-[0.2-50/0.1]
NETC-AST-S-A1-V-[0.2-50/0.1]
NETC-AST-S-A2-C-[0.2-50/0.1]
NETC-AST-S-A2-V-[0.2-50/0.1]
NETC-AST-S-A3-C-[0.2-50/0.1]
NETC-AST-S-A3-V-[0.2-50/0.1]
NETC-AST-S-A4-C-[0.2-50/0.1]
NETC-AST-S-A4-V-[0.2-50/0.1]
NETC-AST-S-A5-C-[0.2-50/0.1]
NETC-AST-S-A5-V-[0.2-50/0.1]
NETC-AST-S-A6-C-[0.2-50/0.1]
NETC-AST-S-A6-V-[0.2-50/0.1]
NETC-ASY-P-A1-C-[0.2-50/0.1]
NETC-ASY-P-A1-V-[0.2-50/0.1]
NETC-ASY-P-A2-C-[0.2-50/0.1]
NETC-ASY-P-A2-V-[0.2-50/0.1]
NETC-ASY-P-A3-C-[0.2-50/0.1]
NETC-ASY-P-A3-V-[0.2-50/0.1]
NETC-ASY-P-A4-C-[0.2-50/0.1]
NETC-ASY-P-A4-V-[0.2-50/0.1]
NETC-ASY-P-A5-C-[0.2-50/0.1]
NETC-ASY-P-A5-V-[0.2-50/0.1]
NETC-ASY-P-A6-C-[0.2-50/0.1]
NETC-ASY-P-A6-V-[0.2-50/0.1]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipCN1 CN2 Number Of Cores Shell type Shell size Cable standard (UL/CSA) Cable color Conductor dimensions
(AWG)
Environment resistant Bend tolerant Cable type Specified Length
(M)

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off[3] 3A124UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off[3] 3A124N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off4A224UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off4A224N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off[5] 5A328UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off[5] 5A328N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off8A428UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off8A428N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off[2] 2A532UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off[2] 2A532N/AGray10N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off4A632UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off4A632N/AGray10N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off[3] 3A124UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off[3] 3A124N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off4A224UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off4A224N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off[5] 5A328UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off[5] 5A328N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off8A428UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off8A428N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off[2] 2A532UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off[2] 2A532N/AGray10N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off4A632UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightCut off4A632N/AGray10N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[3] 3A124UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[3] 3A124N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A224UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A224N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[5] 5A328UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[5] 5A328N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal8A428UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal8A428N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[2] 2A532UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[2] 2A532N/AGray10N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A632UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A632N/AGray10N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[3] 3A124UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[3] 3A124N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A224UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A224N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[5] 5A328UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[5] 5A328N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal8A428UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal8A428N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[2] 2A532UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal[2] 2A532N/AGray10N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A632UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Male relay straightY terminal4A632N/AGray10N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightMark tube only[3] 3A124UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightMark tube only[3] 3A124N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightMark tube only4A224UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightMark tube only4A224N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightMark tube only[5] 5A328UL / CSANavy12Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightMark tube only[5] 5A328N/AGray12N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightMark tube only8A428UL / CSANavy14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightMark tube only8A428N/AGray14N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightMark tube only[2] 2A532UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightMark tube only[2] 2A532N/AGray10N/AN/AV0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightMark tube only4A632UL / CSANavy10Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 6 Day(s) or more Female relay straightMark tube only4A632N/AGray10N/AN/AV0.2 ~ 50

Loading...

Combination Method


Material / Finish

Item Materials Finish
Main Body (Shell) Zinc Alloy (Shell Size 24)
Aluminum Alloy (Shell Size 28, 32)
Satin Chrome-plated
Insulator Epoxy Resin -
Contact Copper Alloy Silver Plating

Characteristics

Number of Cores Shell
Size
Shape Symbol Contact
Array
Rated Current
(A) or less
Rated Voltage
(V) or less
Withstand Voltage
(VAC)
Insulation Resistance
(MΩ or higher)
Contact Resistance
(MΩ or less)
Applicable Electric Wire Operating Temperature
Range
AWG Section Area (mm2) Finished Outer Diameter (mm)
3 24 PM, PF
ADM,
ADF
RM, RF
20 250 1,500 2,000 3 12 3.5 φ11.5 ~ 14.0 -40°C
~
+100°C
32 PM, PF
ADM,
ADF
RM, RF
30 250 2,000 2,000 3 10 5.5 φ15 ~ 19.5
4 24 PM, PF
ADM,
ADF
RM, RF
15 250 1,500 2,000 3 14 2.0 φ11.5 ~
28 PM, PF
ADM,
ADF
RM, RF
20 250 1,500 2,000 3 12 3.5 φ13.6 ~ 16.5
32 PM, PF
ADM,
ADF
RM, RF
30 250 2,000 2,000 3 10 5.5 φ15 ~ 19.5
8 28 PM, PF
ADM,
ADF
RM, RF
15 250 1,500 2,000 3 14 2.0 φ13.6 ~ 16

(Note) For NET connectors, because the earth contact (terminal with mark) is conductive with the body, do not connect wiring other than an earth wire.

Connection Work Method

Common with the JIS standard medium-sized connector NJC

Wire End Processing Dimensions

Product No. Contact
Shape
A B Conductor Cross-Sectional Area
mm2
AWG Iron Tip Temperature °C Soldering Iron
Wattage (W)
mm mm
NET-24-3- PM, PF
ADM
ADF
RM, RF
20 8.0 3.5 12 370 ~ 400 60
NET-24-4- 21 7.0 2.0 14 350 ~ 370 30
NET-28-4- 20 8.0 3.5 12 370 ~ 400 60
NET-28-8- 21 7.0 2.0 14 350 ~ 370 30
NET-32-3- 35 7.0 5.5 10 370 ~ 400 60 ~ 80
NET-32-4- 35 7.0 5.5 10 370 ~ 400 60 ~ 80

Basic Information

Connector type NET Connector manufacturer Nanaboshi Electric Mfg. Co., Ltd. Cable rated voltage(V) 600
Cable shape Circular Shield N/A

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)