  • Please be informed that our office is closed during the upcoming Labour Day Holiday in 2024. We would also like to inform you that there may be a potential delay in response/shipment from the supplier due to the Japan Golden Week holiday which falls from 29th April to 6th May 2024. Click here for details.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

Quartz timer H5CN (H5CN-XCN DC12-48)

Quartz timer   H5CN H5CN-XCN DC12-48

[Features]
· A complete series DIN48 × 48 mm of quartz timers.
· 9.999s, 99.99s, 999.9sd, 99min59s, 99h59min and wide time specifications.
· A type which counts time elapsed or remaining time, and contact or non-contact connection types can be selected in accordance with requirements.
· Power source freely selectable AC100 to 240V.
· The DC specification enables a free choice from 12 to 48V.
· UL and foreign standard CSA were acquired.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

H5CN-XCN DC12-48

Quartz Timer Specifications

H5CN external appearance

H5CN external appearance

  • Rich lineup of DIN 48 × 48 mm quartz timers.
  • A wide range of time specifications: 9.999 s, 99.99 s, 999.9 s, 99 min 59 s and 99 h 59 min.
  • A type which counts time elapsed or remaining time, and contact or non-contact connection types can be selected in accordance with requirements.

Quartz Timer Performance

Variations In Operating Time±0.01% ±0.05 s (for power supply start*1)*2
±0.005% ±0.03 s (for reset start)
(Percentage relative to set value)
Set Error
Voltage Effect
Temperature Effect
Insulation Resistance100 MΩ or more (at 500 V DC megger)
(Between the conductive part terminal and exposed non-charging metal part, between the operation power supply circuit and control output circuit)
Withstand Voltage2,000 V AC, 50/60 Hz, 1 min
(Between the conductive part terminal and exposed non-charging metal part, between the operation power supply circuit and control output circuit)
Impulse Voltage6 kV (between operation power supply terminals)
6 kV (between the conductive part terminal and exposed non-charging metal part)
Noise ResistanceSquare-wave noise by noise simulator
AC: ±2 kV (between operation power supply terminals)
DC: ±480 V (between operation power supply terminals), ±500 V (between input terminals)
Electrostatic Strength8 kV (Malfunction)
VibrationEndurance10 to 55 Hz, half amplitude 0.75 mm, 3 directions, 2 h each
Malfunction10 to 55 Hz, half amplitude 0.5 mm, 3 directions, 10 min each
ShockEndurance300 m/s2, 6 directions, 3 times each
Malfunction100 m/s2, 6 directions, 3 times each
LifeMechanical10 million operations or more
Electrical100,000 operations or more (250 V AC, 3 A, resistive load)
Power Failure Memory Method*3Non-volatile memory (number of writes: 1 million times, data retention: 10 years)
MassApprox. 110 g

*1. Series H5CN-X□NM does not support power supply reset, so this does not apply.
* 2. Total error including variations in operating time, set errors, and the effects of voltage and temperature.
Total error also includes power supply ON time as well as internal circuit and output circuit operating time.
* 3. Series H5CN-X□NM only.

Quartz Timer External Shape And Dimensional Drawing

Series H5CN surface mounting / embedded mounting (common) external shape

Series H5CN surface mounting / embedded mounting (common) external shape

Series H5CN surface mounting / embedded mounting (common) dimensional drawing

Series H5CN surface mounting / embedded mounting (common) dimensional drawing

Refer to the catalog for external shapes and dimensional drawings for model numbers other than those listed above.

Part Number
H5CN-XCN DC12-48
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSTime specifications
(s)
Power Supply Voltage Output Method Rated power supply voltage
(V)
Contact Configuration

SGD 231.11

1 Piece(s) 4 Day(s) or more -1s to 99min59sDedicated to DCRelayDC12 to 48Includes contact 1c

Loading...

  1. 1
 

Basic Information

Type Timer Display method LED Mounting Method Panel / surface mount (shared)
Dimension vertical(mm) 48 Dimension width(mm) 48 Dimension depth(mm) 72.5
Time ranges = N 5 range

Please check the type/dimensions/specifications of the part H5CN-XCN DC12-48 in the Quartz timer H5CN series.

Similar Part Numbers

Part Number
H5CN-XBN AC100-240
H5CN-XBN DC12-48
H5CN-XCN AC100-240
H5CN-XCNM AC100-240
H5CN-XDN AC100-240
H5CN-XDNM AC100-240
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSTime specifications
(s)
Power Supply Voltage Output Method Rated power supply voltage
(V)
Contact Configuration

SGD 229.90

1 Piece(s) 31 Day(s) -0.1s to 999.9sAC-dedicatedRelayAC 100–240Includes contact 1c

SGD 221.43

1 Piece(s) Same day -0.1s to 999.9sDedicated to DCRelayDC12 to 48Includes contact 1c

SGD 221.43

1 Piece(s) 4 Day(s) or more -1s to 99min59sAC-dedicatedRelayAC 100–240Includes contact 1c

SGD 258.94

1 Piece(s) 4 Day(s) or more -1s to 99min59sAC-dedicatedRelayAC 100–240Includes contact 1c

SGD 231.11

1 Piece(s) 4 Day(s) or more -1 min to 99 h 59 minAC-dedicatedRelayAC 100–240Includes contact 1c

SGD 241.70

1 Piece(s) Quote -1 min to 99 h 59 minAC-dedicatedRelayAC 100–240Includes contact 1c

Tech Support