Quartz timer H5AN

Quartz timer   H5AN

[Features]
· The time range has become wider DIN72 × 72 mm quartz timer.
· 1/100th of a second to 9999 hours are covered by one apparatus.
· For the first time, the timer incorporates an external power source supply, and all kinds of sensors can be connected directly.
· Maintenance is possible by removing the wiring from the main body by a draw-out structure.
· The power sources are AC100 to 240V, the product line-up also includes DC specifications.
· The control output simultaneously enabled contact and non-contact connection.
· The standard product has acquired UL and CSA standard.

PDF

Japanese Only

Quartz Timer H5AN Specifications

Quartz Timer H5AN: related image

H5AN external appearance

Quartz Timer H5AN: related image

H5AN dimensional drawing
Units: mm

Note 1. The standard panel cut is as shown in the figure on the upper right. (DIN 43700 compliant)
Note 2. Can be attached to items with a plate thickness of 1 to 5 mm.
Note 3. Securely mount by using the included mounting bracket.

Quartz Timer H5AN: related image

Dimensional drawing when n units are installed side by side
Units: mm

H5AN Type

FormatSeries H5AN-4DSeries H5AN-4DM
Mounting MethodEmbedded mounting, left and right close contact mounting possible
Operation MethodTime Limit Operation, Cumulative Operation
Operation ModeN, F, C, R, K, P, Q (switchable by rotating DIP switch)
Recovery MethodPower supply reset (excluding -M type), external reset, manual reset, automatic reset
External Connection MethodScrew-Fastening Terminal
Input Signal MethodContact: input by contact open/short
Non-contact: input by open collector transistor ON/OFF
Control OutputContact 1c and non-contact output ("H", "L" switchable during operation)
Display MethodNumerical display with 7-segment LED (character height: 10 mm), time up display with LED
Numerical Progression DirectionUP display: Increase from 0 to the set value
DOWN display: Decrease from the set value to 0
Switchable by rotating DIP switch
Number Of Digits4 digits
99.99 s (from 0.01 s) 999.9 s (from 0.1 s) 9,999 s (from 1 s) 99 min 59 s (from 1 s)
999.9 h (from 0.1 h) 9,999 h (from 1 h)
999.9 min (from 0.1 min) 99 h 59 min (from 1 min)
Switchable by rotating DIP switch
Availability Of External Power SupplyExternal Power Supply Available
Availability Of Power Failure MemoryNAON/OFF switchable (switching by DIP switch)

H5AN Ratings

Power Supply VoltageSeries H5AN-4D: 100 to 240 V AC 50/60 Hz, 12 to 24 V DC / 100 V DC*1
Series H5AN-4DM: 100 to 240 V AC 50/60 Hz, 12 to 24 V DC*1
Allowable Voltage Variation Range85 to 110% of power supply voltage
Power ConsumptionApprox. 10 VA (when 240 V AC), approx. 5W (when 24 V DC)
Reset, GatePower supply reset: minimum power supply open time: 0.5 s*2
External reset and gate (contact/non-contact input shared): minimum input signal width: 0.02 s
One-Shot Output Time0.1 to 1 s (variable by using the adjuster on the front panel)
Control OutputContact: 1c 250 V AC, 3 A, resistive load (cosφ = 1)
Non-contact: 30 V DC max, 100 mA max
Minimum applied load 5 V DC, 10 mA (P level, reference)
External Power Supply12 V DC ±10%, 80 mA (ripple 5% or less)
Ambient Operating Temperature-10 to +55°C (No Freezing)
Storage Temperature-25 to +65°C (No Freezing)
Ambient Operating Humidity35 to 85%
Case ExteriorLight Gray (Munsell 5Y7/1)

*1. Ripple content is 20% or less.
*2. Excluding when "power failure memory" is set on the -M type.

H5AN Performance

Variations In Operating Time±0.01% ±0.05 s or less (for power supply start)
±0.005% ±0.03 s or less (for reset start)
(Percentage relative to set value)
Set Error
Voltage Effect
Temperature Effect
Insulation Resistance100 MΩ or more (at 500 V DC megger)
(Between the conductive part terminal and exposed non-charging metal part, between discontinuous contacts)
Withstand Voltage2,000 V AC, 50/60 Hz, 1 min (between the conductive part terminal and exposed non-charging metal part)
750 V AC, 50/60 Hz, 1 min (between discontinuous contacts)
Impulse Voltage6 kV (between operation power supply terminals)
6 kV (between the conductive part terminal and exposed non-charging metal part)
Noise ResistanceSquare-wave noise by noise simulator
±2 kV (between operation power supply terminals) ±500 V (between input terminals)
Electrostatic Strength8 kV (Malfunction)
VibrationEndurance10 to 55 Hz, half amplitude 0.375 mm, 3 directions, 2 h each
Malfunction10 to 55 Hz, half amplitude 0.25 mm, 3 directions, 10 min each
ShockEndurance300 m/s2, 6 directions, 3 times each
Malfunction100 m/s2, 6 directions, 4 times each
LifeMechanical10 million operations or more
Electrical100,000 operations or more (250 V AC, 3 A, resistive load)
Power Failure Memory Method*2Non-volatile memory (number of writes: 1 million times, data retention: 10 years)
MassApprox. 360 g

Refer to the catalog for product information not listed above.

Part Number
H5AN-4D AC100-240
H5AN-4D DC12-24
H5AN-4DM AC100-240
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRated power supply voltage
(V)

SGD 461.01

1 Piece(s) 4 Day(s) or more AC 100–240

SGD 446.49

1 Piece(s) 4 Day(s) or more DC 12–24

SGD 500.94

1 Piece(s) 4 Day(s) or more AC 100–240

Loading...

  1. 1
 

Basic Information

Type Timer Display method LED Mounting Method Panel
Time specifications(s) 0.01s to 9999h Power Supply Voltage AC/DC Output Method Relay/Transistor
Dimension vertical(mm) 72 Dimension width(mm) 72 Dimension depth(mm) 115
Time ranges = N 4 range Contact Configuration Includes contact 1c/does not include contact

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)