  • Please be informed that our office is closed during the upcoming Labour Day Holiday in 2024. We would also like to inform you that there may be a potential delay in response/shipment from the supplier due to the Japan Golden Week holiday which falls from 29th April to 6th May 2024. Click here for details.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

MELSEC-Q Series CC-Link/LT Unit

Part Number

Configured Part Number is shown.

QJ61CL12

MELSEC-Q Series CC-Link/LT Unit Specifications

QJ61CL12 image

QJ61CL12 image

Performance Specifications

Control Specifications
Point Modes4-point mode / 8-point mode / 16-point mode
Maximum Link Points ( ) is for When the Same Input/Output Address is Used4-Point Mode256 points (512 points)
8-Point Mode512 points (1,024 points)
16-Point Mode1,024 points (2,048 points)
Link Points Per Station ( ) is for When the Same Input/Output Address is Used4-Point Mode4 points (8 points)
8-Point Mode8 points (16 points)
16-Point Mode16 points (32 points)
Link Scan Time32 Stations Connected4-Point ModeNumber of points: 128
2.5 Mbps: 0.7 ms
625 kbps: 2.2 ms
156 kbps: 8.0 ms
8-Point ModeNumber of points: 256
2.5 Mbps: 0.8 ms
625 kbps: 2.7 ms
156 kbps: 10.0 ms
16-Point ModeNumber of points: 512
2.5 Mbps: 1.0 ms
625 kbps: 3.8 ms
156 kbps: 14.1 ms
64 Stations Connected4-Point ModeNumber of points: 256
2.5 Mbps: 1.2 ms
625 kbps: 4.3 ms
156 kbps: 15.6 ms
8-Point ModeNumber of points: 512
2.5 Mbps: 1.5 ms
625 kbps: 5.4 ms
156 kbps: 20.0 ms
16-Point ModeNumber of points: 1,024
2.5 Mbps: 2.0 ms
625 kbps: 7.4 ms
156 kbps: 27.8 ms
Communication Specification
Transmission Speed2.5 Mbps / 625 kbps / 156 kbps
Communication MethodBITR method (Broadcastpolling + Interval Timed Response)
Transmission Path TypeT-branch method
Error Control MethodCRC
Number of Connected Devices64 devices
Remote Station Number1 to 64
Master Station Connection PositionConnected to the end of the main line
Communication CableDedicated ribbon cable (0.75 mm2 × 4)
VCTF cable
Flexible cable
Unit Specifications
External Power SupplyVoltage1 to 28.8 V DC
Current0.028 A
Current At Startup0.070 A
Number of Occupied Inputs/Outputs16/32/48/64/128/256/512/1,024 points (I/O assignment: intelligent)
5 V DC Internal Current Consumption0.13 A
External DimensionsHeight (H)98 mm
Width (W)27.4 mm
Depth (D)90 mm
Weight0.09 kg
Part Number
QJ61CL12
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

SGD 269.80

1 Piece(s) Quote

Loading...

  1. 1
 

Basic Information

Type of unit Master Station Transmission Speed 2.5Mbps/625kbps/156kbps Collection Interval 35m(2.5Mbps)/100m(625kbps)/500m(156kbps)

Please check the type/dimensions/specifications of the part QJ61CL12 in the MELSEC-Q Series CC-Link/LT Unit series.