(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Please be informed that our operating hours are from 9:00~15:00 during the upcoming Vesak Day Holiday 2024. Click here for details.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

SSCL3SB, UL-Listed (CL3) Support With Shield

SSCL3SB, UL-Listed (CL3) Support With Shield
  • Volume Discount

300 V shielded cable for fixed signals, CL3/ULAWM2464 standard compliant. A sheath with excellent oil resistance and flexibility is used.

  • VW-1
  • ULAWM
  • ULLISTED
  • For Signal
  • Oil-Resistant
  • Strand Wire
  • Single Shield
  • Twisted Pair
  • 300 V

● Soft oil-resistant sheaths are used.

·This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

Electrical Appliance and Material Safety Law certificate has not been obtained.

PDF

Part Number

Configured Part Number is shown.

Specifications

SSCL3SB, UL-Listed (CL3) Support With Shield:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model NumberAWG SizeNumber of Pairs *4
1P = 2 Cores
Total Length *3
or
Specified Length
SSCL3SB241P1
~
100
(Specify 1 m
Increment)
/
500
/
1000
2P
3P
4P
5P
6P
8P
10P
221P
2P
3P
4P
5P
6P
10P
201P
2P
3P
4P
5P


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* 1 Stock products are indicated with T or A in the price column at right.
* 2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* 3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).
* 4 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering.

More Information

SSCL3SB, UL-Listed (CL3) Support With Shield:Related Image
SSCL3SB, UL-Listed (CL3) Support With Shield:Related Image
SSCL3SB, UL-Listed (CL3) Support With Shield:Related Image

Specifications
Model NumberAWG
Size
Pair No. *1
1P = 2-core
Estimated
Section Area
(mm2) *2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *5
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided
Allowable Current
A (30 °C) *3
Conductor Resistance
Ω / km (20 °C)
Insulation Properties
MΩkm (20 °C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4Thickness
(mm)
Material *3Thickness
(mm)
Material *3
SSCL3SB241P0.2Twisted Pair24.7344.2 90.7 or less30.5 or MoreAC.150011/0.160.61Tin0.26PVC1.140.85PVCCL3
AWM2464
2P46.6543.3 92.6 or less0.90
3P66.7612.8
4P87.2742.4
5P107.7832.2
6P128.51001.9 1.00
8P169.01161.7
10P2010.31421.7
221P0.325.0415.6 58.7 or less30.5 or MoreAC.150017/0.160.760.271.300.85
2P47.2674.3 59.9 or less0.90
3P67.3773.7
4P87.8893.2
5P108.71093.0 1.00
6P129.31282.5
10P2011.51882.2
201P0.525.8567.9 37.6 or less30.5 or MoreAC.150021/0.180.950.361.670.90
2P48.7936.1 38.3 or less1.00
3P68.81085.2
4P89.61334.5
5P1010.41544.2


*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] ‌PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*5 ‌For the outer diameter size of cables, wire sheath (coat), etc.,
refer to "Finished Outer Diameter" in the table above.

Current Reduction Factor
Ambient Temperature (°C)3040506070
Current Reduction Factor1.000.900.780.640.45
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value. If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Ex.) Allowable current value for AWG24 1-pair when the ambient temperature is 40°C: 4.2 x 0.9 = 3.78 (A)

SSCL3SB, UL-Listed (CL3) Support With Shield:Related Image
Part Number
SSCL3SB-22-5P-100
SSCL3SB-24-5P-100
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConductor Cross Section
(mm2)
AWG size
(AWG)
Logarithm Finished outer diameter
(mm)

SGD 551.86

1 Piece(s)Available 4 Day(s) or more 0.3225P8.7

SGD 390.69

1 Piece(s)Available 4 Day(s) or more 0.2245P7.7

Loading...

  1. 1

Basic Information

Overall Length(m) 100 Rated Voltage 300V Shield Present
Properties Oil resistance Representative Standard UL Sheath (outer coating) color Black
Sheath (outer coating) material PVC Insulation body materials PVC Power supply/signal For signals
Other properties Pliability, Noise Resistance

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)