Insulation Resistance Meter Compatible with Solar Panel

Insulation Resistance Meter Compatible with Solar Panel

[Features]
· Capable of accurate measurements even when the PV system is generating power.
· Safe. Not necessary to short-circuit the P phase and N phase.
· Able to be used as a conventional megohmmeter up to 500/1000V.
· With insulation deterioration point determination function (for PV panel measurements only).
· Able to measure generated voltage (DC0 to 999V).

Part Number

Configured Part Number is shown.

Features

●Safe, no need to short circuit P phase and N phase.
●Can measure 500/1000V as a conventional megger.
●With insulation degradation location discrimination function(solar panel measurement only).

Specification

●Rated Measuring Voltage(V/MΩ):500/100, 1000/2000
●Min Display(MΩ):0.01
●DC Voltage(V):DC0 to 999
●SPQ(piece):1
●W x D x H: 170 x 52 x 105mm
●Power Supply: AA Dry Battery x 6(accessory)
Part Number
MIS-PV1
MIS-PV2
MIS-PVS
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipInsulation resistance measuring range (lower limit)
(mΩ)
Test voltage range (lower limit)
(V)
Alternating Current Voltage
(V)
DC Voltage
(V)
Supported number of ranges
(mΩ)
JAN Code Trusco Code

SGD 506.74

1 Piece(s) 10 Day(s) or more 100500---4571206800214758-7520

SGD 758.26

1 Piece(s) 7 Day(s) or more 201250 to 599-2·44571206800221758-7538

SGD 1,512.79

1 Piece(s) 7 Day(s) or more 100500-DC0 to 99924571206800238758-7546

Loading...

  1. 1

Basic Information

Measurement display Digital Insulation resistance measuring range (upper limit)(mΩ) 2000 Test voltage range (upper limit)(V) 1000
Power Supply Dry Cell Battery Battery drive time(h) 5 Minimum Display 0.01
Power supply details Six Double A Batteries (Included) Dimensions(mm) Width 170 x depth 52 x height 105

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)