(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

Electron Counter (DIN 72x72) - H7BX

Electron Counter (DIN 72x72) - H7BX
  • On Sale Till 31/03/2024

[Features]
· Bright, easy to view negative LCD display.
· A new standard DIN72 × 72 mm sized electronic counter.
· High visibility enabled by a negative LCD and back-lighting.
· Checking from a distance enabled by a display color change function (Red<=>Green).
· Simpler operation enabled by using vertical keys.
· All of the basic settings are possible by the dip switch.
· Total preset counter, batch counter, dual counter, tachometer loaded. Can deal with a wide range of inputs with multi
· NPN/PNP input, and compatible with DC two lead sensor.
· UL, CSA acquired.
· Compatible with the CE mark.
· Water resistant structure (only the front part of IP54).

PDF

Japanese Only

Electronic Counter Specifications

H7BX external appearance

H7BX external appearance

H7BX outline drawing

H7BX outline drawing

Rating

FormatSeries H7BX-A/AD1Series H7BX-AW/AWD1
TypePreset CounterPreset Counter / Tachometer
Function1-Stage Preset Counter
Total Preset Counter (Switchable) *1
1-Stage Preset Counter
2-Stage Preset Counter
Total Preset Counter *1
Batch Counter
Dual Counter
Tachometer (Switchable)
RatingPower Supply Voltage*2100 to 240 V AC, 50/60 Hz
24 V AC, 50/60 Hz / 12 to 24 V DC (ripple content is 20% or less)
Allowable Voltage Range85 to 110% of rated power supply voltage (90 to 110% for 12 V DC)
Power ConsumptionSeries H7BX-A/AW: 9.6 VA or less (100 to 240 V AC)
Series H7BX-AD1/AWD1: 8 VA or less (24 V AC), 5.3 W or less (12 to 24 V DC)
Mounting MethodEmbedded Mounting
External Connection MethodScrew-Fastening Terminal
Protective StructureIP54 (Front Part Only)
Input SignalCP1, CP2, Reset 1, Reset 2, Key Protect
CounterMaximum Counting Speed30 Hz, 5 kHz (Switchable) (ON/OFF Ratio 1:1) CP1, CP2 Common Setting
Input ModeAddition, subtraction, addition and subtraction (UP/DOWN A [specified input], UP/DOWN B [individual input],
UP/DOWN C [phase difference input])
Output ModeN, F, C, R, K-1, P, Q, A,
K-2, D, L
N, F, C, R, K-1, P, Q, A,
K-2, D, L, H
One-Shot Time0.01 to 99.99 s
Recovery MethodExternal reset (minimum signal width:1 ms, 20 ms switchable), manual reset,
Automatic reset (internal reset according to operation of C, R, P, Q modes)
TachometerPulse Measurement Method---Periodic Measurement Method (Sampling Cycle: 200 ms)
Maximum Counting Speed---30 Hz, 10 kHz (Switchable)
Measurement Range---30 Hz: 0.01 Hz to 30.00 Hz
10 kHz: 0.01 Hz to 10 kHz
Measurement Accuracy---±0.1% F.S. ±1 digit or less (at 23±5°C)
Output Mode---Upper/lower limit, range, upper limit, lower limit
Auto Zero Time---0.1 to 99.9 s
Start-Up Compensation Timer---0.0 to 99.9 s
Average number of times---OFF / 2 times / 4 times / 8 times
Pre-Scale FunctionAvailable (0.001 To 99.999)
Decimal Point SettingAvailable (Bottom 3 Digits)
Sensor Wait Time290 ms or less (during sensor wait time, input is not acknowledged with control output OFF)
Key Protect InputAnswer speed: approx. 1 s
non-voltage (NPN) input (fixed)
Impedance at short circuit: 1 kΩ or less (at 0 Ω outflow current: approx. 12 mA),
residual voltage at short circuit: 3V or less, impedance when opening: 100 kΩ or more
Input Method
(Excluding Key Protect Input)
Non-voltage (NPN) input / voltage (PNP) input (switchable)
During non-voltage input: impedance at short circuit: 1 kΩ or less (at 0 Ω outflow current: approx. 12 mA),
residual voltage at short circuit: 3 V or less, impedance when opening: 100 kΩ or more
During voltage input: "H" level: 4.5 to 30 V DC, "L" level: 0 to 2 V DC (input resistance approx. 4.7 kΩ)
Power Supply To External Equipment12 V DC (±10%) 100 mA max.
Control OutputRelay output contact: 250 V AC / 30 V DC 3 A
Resistive load (cosø = 1), minimum applied load: 5 V DC 10 mA (P level, reference)
Transistor output: 30 V DC max. 100 mA max.
Residual voltage 1.5 V DC or less (actual power approx. 1 V DC), leak current 0.1 mA or less
Display Method*37-segment negative LCD with backlight
Character height
Count values: 13.5 mm (red/green)
Setting values: 9 mm (green)
Number Of Digits6-digit
-99,999 to 999,999 (-5 digits to +6 digits)
6-digit
When counter: -99,999 to 999,999 (-5 digits to +6 digits)
When tachometer: 0 to 999,999 (6 digits)
Power Failure Memory MethodEEP-ROM (100,000 rewrites or more) data retention: 10 years or more
Operating Temperature Range-10 to +55°C (No Freezing)
Storage Temperature Range-25 to +65℃ (No Freezing)
Ambient Operating Humidity25 to 85% (No Condensation)
Case ColorBlack (N1.5)
AccessoriesBracket for embedded mounting × 2, terminal coverBracket for embedded mounting × 2, terminal cover,
seal for DIP switch setting

Electrical-life curve (reference value)

Resistive Load

Resistive Load

Inductive Load

Inductive Load

Part Number
H7BX-A
H7BX-AD1
H7BX-AW
H7BX-AWD1
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipPower Supply Voltage Classification MAX input frequency (MAX counting speed) (Hz) Power supply voltage details
(V)

SGD 519.09

1 Piece(s) 4 Day(s) or more AC-dedicatedPreset counter30Hz/5kHzAC 100–240

SGD 539.66

SGD 237.45

1 Piece(s) Same day AC/DCPreset counter30Hz/5kHzAC24/DC12 to 24

SGD 591.69

SGD 313.60

1 Piece(s) Same day AC-dedicatedPreset counter/tachometer30Hz/10kHzAC 100–240

SGD 617.10

1 Piece(s) 7 Day(s) or more AC/DCPreset counter/tachometer30Hz/10kHzAC24/DC12 to 24

Loading...

  1. 1
 

Basic Information

Type Total counter Display method LCD Display Digits 6 digits
Mounting Method Panel Panel cut dimensions 68x68 Prescale Available
Representative Standard CE / UL Dimension vertical(mm) 72 Dimension width(mm) 72
Dimension depth(mm) 100 Computing Method Add/subtract/add-subtract

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)