CAN 64 Message FIFO Equipped

CAN 64 Message FIFO Equipped

CAN 64 message FIFO equipped type

[Features]
· 3.3 V signal environment, 3U size CompactPCI CPZ series. Low speed two-channel inter-channel isolated CAN interface product. SJA1000 is used for the CAN controller. Low-speed CAN channel uses TJA1054A for CAN transceiver, and it can communicate supporting Fault-tolerant CAN. The maximum communication speed is 125kbps. Each channel has a CAN controller, and it is possible to set different communication speeds. With the DIP switch, you can select the terminating resistor to be connected.
Equipped with a large capacity FIFO for transmission and reception. Allows for easy and high-speed message transmission and reception without leakage. Equipped with CANbus test functionality for easy checking and analysis of CAN bus operation.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

PCI-485220

 
Part Number
PCI-485220
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHS

SGD 854.89

1 Piece(s) 7 Day(s) or more 10

Loading...

  1. 1

Basic Information

Type Serial communication Bus PCI PCI bracket Standard
Dimension length(mm) 119.91 Dimension width(mm) 60 Communication standard High-speed CAN: CAN 2.0B (Active), ISO11898-2 compliant
Baud Rate High Speed CAN: 60 kbps to 1 Mbps CAN distinction High speed CAN High speed CAN number(Channel) 2
CAN transceiver High speed CAN: SN65HVD251 (equivalent), ISO11898-2 compliant Receiving buffer 64-message FIFO (10μs-increment reception timing added) Transmission buffer 64-message FIFO
CAN types (standard, high performance version, multiple channel version) Advanced Function Version Maximum number of connection units High-speed CAN: 30 units (MAX) Interrupt Function Sent-received message/error status/CAN controller
Insulation type Non-Insulated Resistance Included. This product has a switch which can be set to on/off Controller used SJA1000 (equivalent product)
Error buffer 64 cases (bus error, arbitration lost, etc.) Maximum Transfer Distance(m) 40 CAN controller system clock 24MHz

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)