CC-Link/LT Input/Output Unit (Input/Output)

Caution
Product Description
CC-Link/LT compatible input/output unit.
[Features]
· One of the smallest in size in the industry.
· Terminal block type, connector type, and cable type.
· Can be used as a remote device station.
[Applications]
· For connections with devices in a field network.
Input/Output Unit Type
Screw Terminal Block Type Features And Specifications
The compact unit is one of the smallest in the industry.
You know where to connect to, just by looking at the nameplate on the terminal block.
Input units share a positive common and a negative common.
The terminal block is structured so that 2‑wire method sensors and loads can be connected directly.
Mounting is possible in six orientations.
| Type Name | Input Format | Rated Input Voltage / Current | Number of Input Points | Input Response Time | Output Format | Rated Load Voltage / Current | Number of Output Points | Leak Current When OFF | Output Protection Function | External Connection | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CL1XY4-DT1B2 | DC Input | Positive Common / Negative Common | 24 V DC / 4 mA | 2 points | 1.5 ms | Transistor Output | Sink | 12/24 V DC / 0.1 A | 2 points | 0.1 mA or less | No | 2‑wire method |
| CL1XY8-DT1B2 | DC Input | Positive Common / Negative Common | 24 V DC / 4 mA | 4 points | 1.5 ms | Transistor Output | Sink | 12/24 V DC / 0.1 A | 4 points | 0.1 mA or less | No | 2-wire method |
| CL1XY4-DR1B2 | DC Input | Positive Common / Negative Common | 24 V DC / 4 mA | 2 points | 1.5 ms | Relay Output | - | 30 V DC / 250 V AC 2 A | 2 points | - | No | 2-wire method |
| CL1XY8-DR1B2 | DC Input | Positive Common / Negative Common | 24 V DC / 4 mA | 4 points | 1.5 ms | Relay Output | - | 30 V DC / 250 V AC 2 A | 4 points | - | No | 2-wire method |
Sensor Connector Type (e-CON) Features And Specifications
The compact unit is one of the smallest in the industry.
Two unit mounting methods, DIN rail and screw mounting, to select from.
3‑wire method sensor input is supported.
| Type Name | Input Format | Rated Input Voltage / Current | Number of Input Points | Input Response Time | Output Format | Rated Load Voltage / Current | Number of Output Points | Leak Current When OFF | Output Protection Function | External Connection | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CL2XY16-DTP1C5V | DC Input | Positive Common | 24 V DC / 4 mA | 8 points | 0.5 ms / 1.5 ms or less | Transistor Output | Sink | 24 V DC, 0.1 A | 8 points | 0.1 mA or less | Available | 3‑wire/2‑wire method |
Cable Type Features And Specifications
The compact unit is one of the smallest in the industry.
Storable in a duct, just like cables.
A communication cable and an external equipment connection cable have been integrated for easy wiring.
Both the communication side and the input/output side come with a cable. (50 cm)
| Type Name | Input Format | Rated Input Voltage / Current | Number of Input Points | Input Response Time | Output Format | Rated Load Voltage / Current | Number of Output Points | Leak Current When OFF | Output Protection Function | External Connection | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CL1XY2-DT1D5S | DC Input | Positive Common | 24 V DC / 4 mA | 1 point | 1.5 ms or less | Transistor Output | Sink | 24 V DC, 0.1 A | 1 point | 0.1 mA or less | No | 3‑wire/2‑wire method |