CC-Link Analog Input Unit Terminal Block Type

Brand :
MITSUBISHI
Caution
Product Description
CC-Link/LT analog input unit.
[Features]
· 4 channels.
· Input: -10 to 10 V DC, 0 to 20 mA DC.
· Output (resolution): 0 to 4,000, -4,000 to 4,000.
· Conversion speed: 200 µs / 4 channels.
· Number of occupied stations: 4 stations in 16‑point mode
[Applications]
· Network communication.
CC-Link Analog Input Unit Terminal Block Type Specifications

CL2AD4-B external appearance

CL2AD4-B dimensional outline drawing (unit: mm)
Performance Specifications
| Analog Input Points | 4 points (4 channels) | ||
|---|---|---|---|
| Analog Input | Voltage | -10 to +10 V DC (input resistance: 11 MΩ) | |
| Current | 0 to 20 mA DC (input resistance: 250 Ω) | ||
| Digital Output | -4,096 to +4,095 | ||
| Input/Output Characteristics, Resolution | Input Range | Digital Output Value (Maximum Resolution) | |
| Voltage Input | 0 To 10 V | 0 to 4,000 (2.5 mV) | |
| 0 To 5 V | 0 to 4,000 (1.25 mV) | ||
| 1 To 5 V | 0 to 4,000 (1.0 mV) | ||
| -10 To 10 V | -4,000 to 4,000 (2.5 mV) | ||
| Current Input | 0 To 20 mA | 0 to 4,000 (5 μA) | |
| 4 To 20 mA | 0 to 4,000 (4 μA) | ||
| Precision (Precision With Respect To Maximum Digital Output Value) | Ambient Temperature: 25±5°C | ±0.2% | |
| Ambient Temperature: 0 To 55°C | ±0.4% | ||
| Temperature Coefficient | ±80 ppm/°C (0.0080%/°C) | ||
| A/D Conversion Speed | 200 µs / 4 channels | ||
| Absolute Maximum Input | Voltage | ±15 V | |
| Current | ±30 mA | ||
| Isolation Method | Between communication system and all analog inputs at once: photocoupler insulation, transformer insulation Between power supply system and all analog inputs at once: photocoupler insulation, transformer insulation Between communication system and power supply system: photocoupler insulation, transformer insulation Between channels: non-insulation | ||
| Dielectric Strength | Between communication system and all analog inputs at once, between power supply system and all analog inputs at once, between communication system and power supply system: 500 V AC for 1 minute | ||
| Insulation Resistance | Between communication system and all analog inputs at once, between power supply system and all analog inputs at once, between communication system and power supply system: 10 MΩ or more at 500 V DC | ||
| Protection Grade | IP2X | ||
| Number Of Occupied Stations | 4 stations in 16-point mode | ||
| Unit Power Supply | Voltage | 24 V DC (20.4 to 28.8 V DC, Ripple Ratio within 5%) | |
| Current | 70 mA | ||
| Current At Startup | 570 mA | ||
| External Wiring Connection Method | 14-point Direct Attachment Terminal Block (M3 Screw) | ||
| Mass | 0.15 kg | ||
General Specifications
| Ambient Operating Temperature | 0 to 55℃ | ||
|---|---|---|---|
| Ambient Storage Temperature | -25 to 75℃ | ||
| Ambient Operating Humidity | 5 to 95% RH, assuming no condensation | ||
| Ambient Storage Humidity | 5 to 95% RH, assuming no condensation | ||
| Vibration Resistance | JIS B 3502, IEC 61131-2 compliant | Under Intermittent Vibration | Frequency: 5 to 8.4 Hz, Amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Acceleration: 9.8 m/s2 Sweeps: 10 sweeps in each direction of X, Y and Z |
| Under Continuous Vibration | Frequency: 5 to 8.4 Hz, Amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Acceleration: 4.9 m/s2 | ||
| Impact Resistance | Conforms to JIS B 3502, IEC 61131-2 (147 m/s2, 3 sweeps in 3 directions of X, Y and Z) | ||
| Operating Atmosphere | No corrosive gas | ||
| Operating Altitude | 0 to 2,000 m | ||
| Installation Location | Inside the control panel | ||
| Overvoltage Category | II or lower | ||
| Pollution Degree | 2 or less | ||