Compact 5-Port Solenoid Valve Non-Plug-in JSY1000/3000/5000 Series

Caution
- Refer to the manufacturer's catalog for specification and material details.
- Product images may be representative images only. Please refer to the manufacturer's catalog for shape details.
Product Description
[Features]
・ Size can be reduced by increasing the flow rate
Contributes to space saving, weight reduction, and large flow rate
・ Power consumption: 0.1 W (with power saving circuit), 0.4 W (Standard)
・ Prepare 4-position dual 3-port valve
・ Prepare back piping (A and B Port)
・ Manifold model: JJ5SY1, JJ5SY3, JJ5SY5
Product Specifications
Internal pilot specifications
Valve part number display method (With 2 mounting screws)

Valve replacement parts
Pilot valve part number display method (For JSY1000)

* The pilot valve does not include the clip.
Valve specifications
| Valve structure | Rubber seal | |||
|---|---|---|---|---|
| Operating fluid | Air | |||
| Internal pilot operating pressure range MPa | 2-position single | 0.15 to 0.7 | ||
| 2-position double | 0.1 to 0.7 | |||
| 3 positions | 0.2 to 0.7 | |||
| 4-position, dual 3-port valve | 0.15 to 0.7 | |||
| External pilot operating pressure range MPa | Operating pressure range | -100 kPa to 0.7 | ||
| Pilot Pressure Range | 2-position single | 0.25 to 0.7 | ||
| 2-position double | ||||
| 3 positions | ||||
| Ambient and operating fluid temperatures °C | -10 to +50 (no freezing) | |||
| Maximum Operating Frequency Hz | JSY1000 JSY3000 | 2 Position Single, Double | 5 | |
| 4-position, dual 3-port valve | ||||
| 3 positions | 3 | |||
| JSY5000 | 2 Position Single, Double | 5 | ||
| 4-position, dual 3-port valve | 3 | |||
| 3 positions | 3 | |||
| Manual | Non-locking push type | |||
| Push-turn locking slotted type | ||||
| Push-turn locking hand-operated type | ||||
| Pilot Exhaust Method | Internal pilot | Individual exhaust type | ||
| External pilot | ||||
| Lubrication | Not required | |||
| Mounting orientation^*1) | Free | |||
| Impact resistance / vibration resistance^*1) m/s^2 | 150/30 | |||
| Protective structure | IP40 | |||
| Electrical Entry | L plug connector (L), M plug connector (M) | |||
| Coil rated voltage (V) | 24 V DC | |||
| Allowable voltage fluctuation | JSY1000 | -7 to +10% of rated voltage (24 V DC) | ||
| JSY3000/5000 | ±10% of rated voltage | |||
| Power consumption: W | DC | Standard | JSY3000/5000 | 0.4 |
| With power saving circuit | JSY1000 | 0.2^*2) [Inrush 0.5, Holding 0.2] | ||
| JSY3000/JSY5000 | 0.1 [Inrush 0.4, Holding 0.1] | |||
| Surge voltage suppressor | Diode | |||
| Indicator light | LED | |||
Impact resistance: No malfunction when tested once for each of the axial and perpendicular directions of the main valve and armature, energized and non-energized conditions. (Initial value)
Vibration resistance: No malfunction when tested under 45 to 2,000 Hz 1 sweep, axial and perpendicular directions of the main valve / armature, energized and non-energized conditions. (Initial value)
*2) The JSY1000 series is set only with a power saving circuit, and the standard (without a power saving circuit) is not supported.
Response time, valve weight
| Series | Sealing method | Part number | Switching method | Response time ms (at 0.5 MPa)*) | Mass g |
|---|---|---|---|---|---|
| Standard | |||||
| With indicator light, surge voltage suppressor | |||||
| Z-Type | |||||
| JSY1000 | Rubber seal | JSY1140T | 2-position single | 15 | 17 |
| JSY1240T | 2-position double | 5 | 24 | ||
| JSY1 (3/4/5) 40T | 3 positions | 13 | 25 | ||
| JSY1 (A/B/C) 40T | 4-position, dual 3-port valve | 14 | 24 | ||
| JSY3000 | JSY3140 | 2-position single | 27 | 34 | |
| JSY3240 | 2-position double | 10 | 49 | ||
| JSY3 (3/4/5) 40 | 3 positions | 30 | 52 | ||
| JSY3 (A/B/C) 40 | 4-position, dual 3-port valve | 27 | 48 | ||
| JSY5000 | JSY5140 | 2-position single | 42 | 66 | |
| JSY5240 | 2-position double | 13 | 83 | ||
| JSY5 (3/4/5) 40 | 3 positions | 40 | 93 | ||
| JSY5 (A/B/C) 40 | 4-position, dual 3-port valve | 41 | 80 |
*) Based on dynamic performance test, JIS B 8419: 2010 (Coil temperature 20°C, rated voltage)
Pilot valve replacement method

Removal procedure
1) Hook the clip from the adapter plate into the concave groove with a flat-blade screwdriver, etc., and remove it.
2) Remove the pilot valve in the direction of the arrow. (Please also remove the gasket.)
Installation procedure
1) Attach the pilot valve to the adapter plate.
2) Insert the clip into the adapter plate. Insert the clip so that it does not come out of the end face of the adapter plate.
*) Make sure that the gasket is attached to the pilot valve.