Refrigerated Air Dryer IDF60/70/80/90 Series
Caution
- Refer to the manufacturer's catalog for specification and material details.
- The product images are representative only. Please refer to the manufacturer's catalog for shape details.
Product Description
This is a refrigerated air dryer, IDF60/70/80/90 Series.
[Features]
・ Suitable for high temperature environments
・ Increased air flow capacity
・ A new stainless steel heat exchanger is used to reduce loads on the refrigerator
・ Improved maintainability
・ Improved resistance to contaminants and longer lifespan for the auto drain valve
・ It protects pneumatic equipment from moisture
Drawing
IDF60,70,80,90

Foundation Bolt Set
Plumbing adapter


IDF-BP339
IDF-BP340
IDF-BP341



Product Specifications
Product Specifications
| Specifications | Model | ||||||
|---|---|---|---|---|---|---|---|
| IDF60 | IDF70 | IDF80 | IDF90 | ||||
| Range of use^*1) | Operating fluid | Compressed Air | |||||
| Inlet air temperature °C | 5 to 65 | ||||||
| Inlet air pressure (MPa) | 0.15 to 1.0^*9) | ||||||
| Ambient temperature (humidity) °C | 2 to 45 (Relative humidity 85% or less) | ||||||
| Rating^*4) | Air flow capacity m^3/min | Standard condition (ANR)^*2) | 50 Hz | 5.3 | 7.5 | 10.9 | 13.5 |
| 60 Hz | 6.1 | 8.6 | 12.8 | 15.5 | |||
| Compressor Suction state^*3) | 50 Hz | 5.6 | 8.0 | 11.6 | 14.3 | ||
| 60 Hz | 6.5 | 9.1 | 13.6 | 16.4 | |||
| Inlet air pressure (MPa) | 0.7 | ||||||
| Inlet air temperature °C | 35 | 40 | |||||
| Ambient temperature °C | 32 | ||||||
| Outlet air pressure dew point °C | 10 | ||||||
| Power supply voltage (frequency) | Single-phase 200 V AC (50 Hz), single-phase 200/220 V AC (60 Hz) Allowable voltage fluctuation ±10%^*5) | ||||||
| Maximum air flow capacity | Amount of air calculated by correction coefficient | ||||||
| Electric specifications | Power consumption^*6) 50/60 Hz W | 770/910 | 1260/1590 | 1770/2170 | 2270/2960 | ||
| Current consumption^*6) 50/60 Hz A | 4.2/4.6 | 6.7/7.9 | 9.7/10.9 | 11.8/14.8 | |||
| Compatible earth leakage circuit breaker capacity^*7) A | 10 | 15 | 20 | 30 | |||
| Cooling system | Air-cooled refrigeration type | ||||||
| Refrigerant | R410A (HFC) GWP: 2088^*8) | ||||||
| Refrigerant filling amount g | 390±10 | 530±10 | 630±10 | 780±10 | |||
| Auto drain | Float type (Normally open minimum operating pressure: 0.1 MPa) | ||||||
| Piping connection port diameter | R1 | R1 1/2 | R2 | ||||
| Weight (kg) | 49 | 68 | 95 | 110 | |||
| Accessories | Drain tube (ø12: 3.5 m), drain tube holder, instruction manual | ||||||
*1) The range of use does not guarantee the use with the rated air flow capacity.
*2) Indicates the air flow capacity under standard temperature (ANR) [20°C, atmospheric pressure, relative humidity 65%].
*3) Indicates the air flow capacity when converted to the air compressor suction state [32°C atmospheric pressure, relative humidity 75%].
*4) If the usage conditions differ from the ratings, select the model according to the model selection method, or calculate the flow rate that can be processed according to the customer's usage conditions by correcting the air flow capacity (this page).
*5) Do not use in a state of continuous voltage fluctuation.
*6) It is a characteristic value at the time of rating, not a guaranteed value. Do not use it for the setting value of the thermal relay.
*7) Products other than option R are not equipped with an earth leakage circuit breaker. Purchase an earth leakage circuit breaker separately. Use a sensitivity current of 30 mA.
*8) This is the value of IPCC4 AR4. The value of the Law Concerning the Discharge and Control of Fluorocarbons is R410A GWP: 2,090.
*9) By selecting option L or option V, you can use up to 1.6 MPa.
Standard table

Foundation Bolt Set
Plumbing adapter