3-Port Solenoid Valve, Body Ported / Base Mounted, Elastic Body Seal, VZ300 Series

Caution
- Refer to the manufacturer's catalog for specification and material details.
- Product images may be representative images only. Please refer to the manufacturer's catalog for shape details.
Product Description
[Features]
· The pilot valve does not require any special measures in regards environmental protection
· It can also be used as a selector valve or divider valve
Drawing
Direct piping type

Base Mounting Type (with Sub-Plate)

Product Specifications
Product Specifications
| Operating fluid | Air | |
|---|---|---|
| Operating pressure range MPa | Internal Pilot Type | 0.15 to 0.7 |
| Ambient and fluid temperature (°C) | -10 to 50 (No freezing. please refer to appendix 44.) | |
| ^*1) Response time ms (at 0.5 MPa) | 20 or less | |
| Maximum operating frequency (Hz) | 10 | |
| Flow rate characteristics | See table below | |
| ^*2) Manual operation | Non-locking push type Screwdriver-operated locking type, hand-operated locking type | |
| Pilot Exhaust Method | Pilot valve individual exhaust type, main valve / pilot valve common exhaust type | |
| Lubrication | Not required | |
| Mounting orientation | Free | |
| ^*3) Impact resistance / vibration resistance m/s^2 | 300/50 | |
| Protective structure | Dust-proof | |
*1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature of 20°C, at rated voltage, without surge voltage suppressor)
*2: Operating torque with locking type manual operation is 0.2 N⋅m or less.
*3) Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunction when tested under 45 to 2,000 Hz 1 sweep, axial and perpendicular directions of the main valve / armature, energized and non-energized conditions. (Initial value)
Product Specifications
| Electrical Entry | Grommet (G)/(H), L plug connector (L), M plug connector (M), DIN terminal (D) | ||
|---|---|---|---|
| Coil rated voltage (V) | AC 50/60 Hz | 100, 200, ※24, ※48, ※110, ※220 | |
| DC | 24, ※6, ※12, ※48 | ||
| Allowable voltage fluctuation % | -15% to +10% of rated voltage | ||
| ^*) Power consumption W [Current value (mA)] | DC | 1.8 (with indicator light: 2.1) [24 V DC: 75 (with indicator light: 87.5)] | |
| ^*) Apparent power VA [Current value (mA)] | AC | Start | 4.5/50 Hz, 4.2/60 Hz (100 V AC: 45/50 Hz, 42/60 Hz 200 V AC: 22.5/50 Hz, 21/60 Hz) |
| Holding | 3.5/50 Hz, 3/60 Hz (100 V AC: 35/50 Hz, 30/60 Hz 200 V AC: 17.5/50 Hz, 15/60 Hz) | ||
| Surge voltage suppressor | DC: Diode, AC: ZNR | ||
| Indicator light | DC: LED (red), AC: Neon bulb | ||
*At rated voltage