Multistage Ejector ZL212 Series

Caution
- The product images are representative images only. Please refer to the manufacturer's catalog for details of the types available
Product Description
Energy-saving, large flow rate, 3-stage diffuser construction
[Features]
· A 250% increase in the suction flow rate due to the 3-stage diffuser construction.
A 20% decrease in air consumption (compared to the 1-stage nozzle type with a nozzle diameter of ø1.3)
· Diffusers are stacked and integrated
· Compact size and large flow rate (twice the flow rate of ZL112)
Multistage Ejector ZL212 Series Specifications

Standard type external appearance

Type with vacuum pressure gauge external appearance

Type with digital pressure switch for vacuum external appearance

Type with adapter external appearance

Port exhaust type external appearance
Ejector Specifications
| Model | ZL212 |
|---|---|
| Nozzle Diameter | 1.2 mm × 2 |
| Maximum Suction Flow Rate | 200 L/min (ANR) |
| Air Consumption | 126 L/min (ANR) |
| Maximum Vacuum Pressure | -84 kPa |
| Maximum Operating Pressure | 0.7 MPa |
| Supply Pressure Range | 0.2 to 0.5 MPa |
| Standard Supply Pressure | 0.4 MPa |
| Operating Temperature Range | 5 to 50°C |
Weight Table
| ZL212 | 700 g |
|---|---|
| Port Exhaust Specifications | +300 g |
| Digital Pressure Switch For Vacuum Specifications (Excluding Lead Wire) | +43 g |
| Digital Pressure Switch For Vacuum Specifications (Including 3-Core Lead Wire) | +81 g |
| Digital Pressure Switch For Vacuum Specifications (Including 4-Core Lead Wire) | +85 g |
| Valve Specifications (Per Piece) | +45 g |
Product Structural Drawing

Multistage Ejector ZL212 Series structural drawing
Components
| Number | Part Name | Note |
|---|---|---|
| 1 | Suction Cover | - |
| 2 | Front Cover A | - |
| 3 | End Plate | - |
| 4 | Body | - |
| 5 | Vacuum Sensor Unit | - |
| 6 | Nozzle | - |
| 7 | Diffuser | - |
| 8 | Detent Plug | Other than vacuum switch |
| Lead Wire Cover | Vacuum switch specifications |
Replacement Parts
| Number | Part Name | Material | Part Number |
|---|---|---|---|
| 9 | Sound-Absorbing Material A | PVA sponge | ZL212-SP01 (Set no. for 9 and 10) |
| 10 | Sound-Absorbing Material | PVA sponge |
Drawing / ZL212 Series
(Unit: mm)

Standard ZL212 dimensional drawing

Port Exhaust ZL212P dimensional drawing

ZL212-GN with vacuum adapter dimensional drawing

Multistage Ejector ZL212 Series common dimensional drawing / Type with digital pressure switch for vacuum, A section - dimensional drawing
Notes
- *Operating Ejector Valves
When the air supply valve is turned ON, a vacuum is generated by the flow of compressed air from the nozzle to the diffuser. When the vacuum release valve is turned ON, the vacuum is quickly released as air passes through the vacuum break flow adjusting needle and flows to the vacuum port. - *Operating Environment
Do not expose to direct sunlight. - *Refer to the manufacturer's catalog for product information not detailed above.