Pressure Switch Reed Switch Type IS10 Series

Caution
- Product images may be representative images. Refer to the manufacturer's catalog for details
Product Description
Pressure switch / contact reed switch type.
[Features]
· 16% weight reduced, 11% smaller (compared to IS1000)
· Compatible with 100 V AC/DC
・ Set pressure range: 0.1 to 0.4 MPa
· Service lifespan: 5 million cycles
· It can be connected to modular type / F.R.L. combination
Specifications of Pressure Switch / Lead Switch Type IS10 Series

External dimensions of IS10 series

Pressure switch usage example
Specifications
| Model | IS10-01 |
|---|---|
| Fluid | Air and inert gas |
| Proof Pressure | 1.0 MPa |
| Maximum operating pressure | 0.7 MPa |
| Set pressure range | 0.1 to 0.4 MPa Option: 0.1 to 0.6 MPa |
| Ambient and fluid temperature | -5~+60℃ (No freezing) |
| Contact | 1a |
| Scale error | ±0.05 MPa or less |
| Hysteresis | Fixed 0.08 MPa or less |
| Repeat accuracy | ±0.05 MPa or less |
| Wiring specifications | Grommet type / lead wire length 0.5 m Option: 3 m, 5 m |
| Protective Enclosure | IP40 equivalent |
| Connection port size | 1/8 |
| Weight | 62 g |
Switch characteristics
| Max. Contact Capacity | AC2VA, DC2W | ||
|---|---|---|---|
| Operating voltage AC, DC | 24 V or less | 48 V | 48V |
| Maximum operating current and range | 50 mA | 40 mA | 20 mA |
Electric circuit

Electrical circuit of IS10 Series (Up to 100 V AC/DC)
JIS symbol

JIS symbol of IS10 Series
Pressure setting range

IS10 Series pressure setting range graph
Dimensions / structural drawing
(Units: mm)

IS10 Series dimensions / structural drawing
| Number | Part Name | Material |
|---|---|---|
| 1 | Body | ZDC |
| 2 | Switch assembly | - |
| 3 | Shield plate | Steel strip |
| 4 | Cover | Steel strip |
| 5 | Adjustment screw | Brass |
| 6 | Hex Nut | Brass |
| 7 | Moving screw | PBT |
| 8 | Spring | SUS |
| 9 | Magnet | - |
| 10 | Piston | POM |
| 11 | Piston packing | NBR |
| 12 | Scale plate | PC |
Pressure switch for modular F.R.L. connection
Pressure switch with spacer
(Units: mm)

External appearance of IS10M (pressure switch with spacer)

Dimensional drawing of IS10M (pressure switch with spacer)
| Model | A | B | C | D | Compatible models |
|---|---|---|---|---|---|
| IS10M-20-A | 11 | 74 | 64 | 28 | AC20□-A |
| IS10M-30-A | 13 | 85 | 71 | 30 | AC25□-A, AC30□-A |
| IS10M-40-A | 15 | 93 | 75 | 36 | AC40□-A |
| IS10M-50-A | 17 | 97 | 77 | 44 | AC40□-06-A |
| IS10M-60-A | 22 | 91 | 67 | 53 | AC50□-B, AC55□-B, AC60□-B |
*) A separate spacer is required for modular connection.
Pressure switch with piping adapter
(Units: mm)

External appearance of IS10E (pressure switch with piping adapter)

Dimensional drawing of IS10E (pressure switch with piping adapter)
| Model *1) | Connection port size | A | B | C | D | E | Compatible models |
|---|---|---|---|---|---|---|---|
| IS10E-20□01-A | 1/8 | 30 | 66 | 55 | 28 | 16 | AC20□-A |
| IS10E-20□02-A | 1/4 | ||||||
| IS10E-20□03-A | 3/8 | ||||||
| IS10E-30□02-A | 1/4 | 32 | 73 | 59 | 30 | 13 | AC25□-A, AC30□-A |
| IS10E-30□03-A | 3/8 | ||||||
| IS10E-30□04-A | 1/2 | ||||||
| IS10E-40□02-A | 1/4 | 32 | 79 | 61 | 37 | 13 | *2)AC40□-A |
| IS10E-40□03-A | 3/8 | ||||||
| IS10E-40□04-A | 1/2 | ||||||
| IS10E-40□06-A | 3/4 |
*1) □ in the model number indicates the type of connection thread. It is necessary to enter no symbol for Rc, "N" for NPT or "F" for G.
*2) It cannot be mounted on AC40□-06-A.
* A separate spacer is required for modular connection.
* When installing a pressure switch on the AC40□-06-A, it is possible by screwing the IS10-01S into the piping adapter E500-□06-A-X501 (with Rc 1/8 thread on the top surface). Please contact the manufacturer support center for the assembled products.
*See the SMC catalog for information other than that detailed above.