Compact Direct Operated 2/3 Port Solenoid Valve For Chemical Liquids LVM09/090 Series

Compact Direct Operated 2/3 Port Solenoid Valve For Chemical Liquids LVM09/090 Series

Base mounted type valve.
[Features]
· Maximum change in volume of 0.01 μL when opening or closing the valve.
· Optional power-saving circuit.
· Space saving.
[Applications]
· Ideal for various types of analytic and testing devices.

(i)Caution

  • Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.
  • Refer to the manufacturer's catalog for specification and material details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.​

PDF

Part Number

Configured Part Number is shown.

Compact Direct Operated 2/3 Port Solenoid Valve For Chemical Liquids LVM09/090 Series Specifications

Base Mounted Type (Without Sub-Plate) external appearance

Base Mounted Type (Without Sub-Plate) external appearance

Flow Rate Characteristics

  • Water: Kv 0.015 / Cv 0.018
  • Air: C 0.06 / b 0.2

*Kv, Cv values conform to JIS B 2005:1995. C and b values conform to JIB B8390:2000.

ModelBase Mounted Type
LVM09R3LVM09R4LVM095R
Valve StructureDiaphragm type direct acting poppet (rocker type)
Valve TypeN.C.N.O.Universal
Number of Ports23
Fluids*1Air, water, deionized water (pure water), diluent, detergent
Operating Pressure Range-75 kPa to 0.2 MPa
Orifice Diameter1.1 mm
Response Time*810 ms or less (with pneumatic pressure)
Leakage RateZero for both internal and external parts (with hydraulic pressure)
Proof Pressure*20.3 MPa
Ambient Operating Temperature*90 to 50°C
Operating Fluid Temperature*90 to 50°C (no freezing)
Volume of Valve Chamber*318 μL
Mounting Orientation*4Free
EnclosureIP40 equivalent
Weight20 g
Rated Voltage12, 24 V DC
Allowable Voltage Fluctuation*5±10% of rated voltage
Coil Insulation TypeClass B
Power Consumption
(Current: at 24‑V Rated Voltage)
Standard Type2 W
(0.08 A)
With power-saving circuitInrush3.3 W
(0.14 A)
Holding0.9 W
Coil Switching Noise*650 dB

*1: Select an appropriate material for the wetted parts according to the type of fluid to be used. Be sure to check the chemical resistance beforehand.
*2: Indicates pressures which do not cause breakage or cracks after a 1 minute airtight test.
*3: Indicates the volume of the clearance inside the volume chamber after the volume of the diaphragm has been subtracted.
*4: As the body (orifice shape) is designed to eliminate residual liquid, mounting in a vertical orientation with the coil facing upward is recommended. If liquid pooling is not an issue, it may be installed in any orientation.
*5: If response speed is considered critical, take adequate regulations to prevent voltage fluctuations on the negative side.
*6: This value is depending on the measurement conditions and the sound level may change depending on the measurement conditions.
*7: See the SMC catalog if the valve is to be energized continuously for extended periods of time.
*8: According to JIS B8419:2010
{Value at an ambient and fluid temperature of 25°C, at rated voltage, at the maximum operating pressure (air) and when the N.C. (IN) port is pressurized}
The response time may vary depending on the supply pressure, fluid quality, piping conditions, ambient temperature, etc.
*9: Note that when the diaphragm material is Kalrez, the valve changeover time becomes significantly longer at ambient and fluid temperatures of 15°C or less in comparison to at room temperature (roughly 25°C).

  •  

Diagram - Base Mounted Type

LVM09R3 diagram

LVM09R3 diagram

LVM09R4 diagram

LVM09R4 diagram

LVM095R diagram

LVM095R diagram

Component Parts: LVM09R3, 09R4, 095R

NumberPart NameMaterial
1PlatePEEK
2Diaphragm AssemblyEPDM, FKM, Kalrez
3BodyPBT
4Slide Bushing AssemblyPPS, SUS
5Armature Assembly-
6Coil Assembly-
7Lead Wire-
8MoldPET
9O-RingNBR
10Interface GasketEPDM, FKM, Kalrez

Drawing

 

(Units: mm)

 

Base Mounted Type LVM09R3-□□-□ (N.C.) / LVM09R4-□□-□ (N.O.) / LVM095R-□□-□ (Universal)

LVM09R3-□□-□ (N.C.) / LVM09R4-□□-□ (N.O.) / LVM095R-□□-□ (universal) dimensional drawing

LVM09R3-□□-□ (N.C.) / LVM09R4-□□-□ (N.O.) / LVM095R-□□-□ (universal) dimensional drawing

*Dotted line indicates with the power-saving circuit.

Interface Recommended Dimensions

LVM09R3-□□-□ (N.C.) / LVM09R4-□□-□ (N.O.) / LVM095R-□□-□ (universal) image of recommended interface dimensions

LVM09R3-□□-□ (N.C.) / LVM09R4-□□-□ (N.O.) / LVM095R-□□-□ (universal) image of recommended interface dimensions

*Surface roughness for LVM09R3 and LVM095R is Rz3.2 or less / Surface roughness for LVM09R4 is Rz3.2 or less

Precautions

  • *See the SMC catalog for information other than that detailed above.
  • *Pictures are of representational models.
Part Number
LVM09R3-5A
LVM09R3-5A-3-Q
LVM09R3-5C-6
LVM09R3-5C-6-Q
LVM09R3-6A
LVM09R3-6A-3-Q
LVM09R3Y1-5A-6-Q
LVM09R4-5A
LVM09R4-5A-Q
LVM09R4-6B-3-Q
LVM09R4Y1-6B-3
LVM09R4Y1-6B-3-Q
LVM095R-5A
LVM095R-5A-3-Q
LVM095R-5A-Q
LVM095R-6A
LVM095R-6A-3-Q
LVM095R-6A-6
LVM095R-6A-6-Q
LVM095RY1-5A-3
LVM095RY1-5A-3-Q
LVM095RY1-5A-6
LVM095RY1-5A-6-Q
LVM095RY1-5C-3
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipSwitching Type Voltage Power consumption
(W)
Lead wire length
(mm)
Liquid-contacting parts material Functions CE compliant

SGD 79.68

1 Piece(s) Quote Normally Closed24 V DC2150Plate: PEEK / Diaphragm: EPDMStandard TypeNone

SGD 89.25

1 Piece(s) Quote Normally Closed24 V DC2300Plate: PEEK / Diaphragm: EPDMStandard TypeCE compliant

SGD 177.92

1 Piece(s) Quote Normally Closed24 V DC2600Plate: PEEK / Diaphragm: KalrezStandard TypeNone

SGD 184.33

1 Piece(s) Quote Normally Closed24 V DC2600Plate: PEEK / Diaphragm: KalrezStandard TypeCE compliant

SGD 79.68

1 Piece(s) Quote Normally Closed12 V DC2150Plate: PEEK / Diaphragm: EPDMStandard TypeNone

SGD 89.25

1 Piece(s) Quote Normally Closed12 V DC2300Plate: PEEK / Diaphragm: EPDMStandard TypeCE compliant

SGD 125.30

1 Piece(s) Quote Normally Closed24 V DCInrush: 3.3 / Holding: 0.9600Plate: PEEK / Diaphragm: EPDMWith power-saving circuitCE compliant

SGD 79.68

1 Piece(s) Quote Normally Open24 V DC2150Plate: PEEK / Diaphragm: EPDMStandard TypeNone

SGD 86.10

1 Piece(s) 41 Day(s) Normally Open24 V DC2150Plate: PEEK / Diaphragm: EPDMStandard TypeCE compliant

-

1 Piece(s) Quote Normally Open12 V DC2300Plate: PEEK, Diaphragm: FKMStandard TypeCE-compliant product

-

1 Piece(s) Quote Normally Open12 V DCInrush: 3.3 / Holding: 0.9300Plate: PEEK, Diaphragm: FKMWith power-saving circuitNot compliant with CE

-

1 Piece(s) Quote Normally Open12 V DCInrush: 3.3 / Holding: 0.9300Plate: PEEK, Diaphragm: FKMWith power-saving circuitCE-compliant product

SGD 79.68

1 Piece(s) Quote Universal24 V DC2150Plate: PEEK / Diaphragm: EPDMStandard TypeNone

SGD 89.25

1 Piece(s) Quote Universal24 V DC2300Plate: PEEK / Diaphragm: EPDMStandard TypeCE compliant

SGD 86.10

1 Piece(s) Quote Universal24 V DC2150Plate: PEEK / Diaphragm: EPDMStandard TypeCE compliant

SGD 79.68

1 Piece(s) Quote Universal12 V DC2150Plate: PEEK / Diaphragm: EPDMStandard TypeNone

SGD 89.25

1 Piece(s) Quote Universal12 V DC2300Plate: PEEK / Diaphragm: EPDMStandard TypeCE compliant

SGD 83.88

1 Piece(s) Quote Universal12 V DC2600Plate: PEEK / Diaphragm: EPDMStandard TypeNone

SGD 90.30

1 Piece(s) Quote Universal12 V DC2600Plate: PEEK / Diaphragm: EPDMStandard TypeCE compliant

SGD 113.17

1 Piece(s) Quote Universal24 V DCInrush: 3.3 / Holding: 0.9300Plate: PEEK / Diaphragm: EPDMWith power-saving circuitNone

SGD 120.00

1 Piece(s) Quote Universal24 V DCInrush: 3.3 / Holding: 0.9300Plate: PEEK / Diaphragm: EPDMWith power-saving circuitCE compliant

SGD 119.00

1 Piece(s) Quote Universal24 V DCInrush: 3.3 / Holding: 0.9600Plate: PEEK / Diaphragm: EPDMWith power-saving circuitNone

SGD 125.30

1 Piece(s) Quote Universal24 V DCInrush: 3.3 / Holding: 0.9600Plate: PEEK / Diaphragm: EPDMWith power-saving circuitCE compliant

SGD 207.32

1 Piece(s) Quote Universal24 V DCInrush: 3.3 / Holding: 0.9300Plate: PEEK / Diaphragm: KalrezWith power-saving circuitNone

Loading...

  1. 1
 

Basic Information

Type Electromagnetic Type Applicable Fluid Air / Water / Chemical Operating Environment Standard
Connection Type Others Driving Type Linear Motion Type Orifice Dia.(Ø) 1.1
Operating Temperature Range(°C) 0::50 Body Material Resin Insulation Class B
Pipe opening type (details) Base Mounted Type

Tech Support