Air Slide Table / MXQ Series

Caution
- Refer to the catalog for product specifications.
- CAD data is not supported by some of the model numbers
- Product images may be representative images. Refer to the catalog for details.
Product Description
An air slide table made by SMC
[Features]
· Integrated guide rail and table.
· A circulation-type linear guide for high rigidity and precision.
· Air slide table for precision assembly.
· A symmetrical type is also available as standard.
· An auto switch attaching groove is provided in consideration of safety.
· Wide range of options.
· Improved load resistance.
· Improved mounting repeatability of workpieces and bodies.
· Reinforced end plate part.
Product Specification
Specifications
| Inner diameter (mm) | 6 | 8 | 12 | 16 | 20 | 25 |
|---|---|---|---|---|---|---|
Pipe connection port diameter | M5 x 0.8 | Rc1/8, NPT1/8, G1/8 | ||||
Operating fluid | Air | |||||
Operation method | Double Acting | |||||
Operating pressure | 0.15-0.7 Mpa | |||||
Proof pressure | 1.05 MPa | |||||
Ambient temperature and operating fluid temperature | -10 to 60°C | |||||
Operating speed range (Average operating speed)note) | 50-500 mm/s (adjuster option/metal stopper: 50-200 mm/s) | |||||
Cushion | Rubber cushion (standard, adjuster option/rubber stopper) Shock absorber (adjuster option/shock absorber) None (adjuster option/metal stopper) | |||||
Lubrication | Lubrication-free | |||||
Auto Switch | Mechanical-contact auto switch (2-wire type / 3-wire type) Non-contact auto switch (2-wire type / 3-wire type) Two-color indicator non-contact auto switch (2-wire type / 3-wire type) | |||||
Stroke length tolerance | +10 mm | |||||
Note: Average operating speed: The speed obtained by dividing the stroke by the time from the start of operation to reaching the end.
Theoretical Output
By adopting a dual rod, double the output of a conventional cylinder can be achieved.
(Unit: N)
| cylinder inner diameter (mm) | rod diameter (mm) | Operating Direction | Pressure Receiving Area (mm2) | Operating Pressure (MPa) | |||||
|---|---|---|---|---|---|---|---|---|---|
| 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | ||||
| 6 | 3 | OUT | 57 | 11 | 17 | 23 | 29 | 34 | 40 |
| IN | 42 | 8 | 13 | 17 | 21 | 25 | 29 | ||
| 8 | 4 | OUT | 101 | 20 | 30 | 40 | 51 | 61 | 71 |
| IN | 75 | 15 | 23 | 30 | 38 | 45 | 53 | ||
| 12 | 6 | OUT | 226 | 45 | 68 | 90 | 113 | 136 | 158 |
| IN | 170 | 34 | 51 | 68 | 85 | 102 | 119 | ||
| 16 | 8 | OUT | 402 | 80 | 121 | 161 | 201 | 241 | 281 |
| IN | 302 | 60 | 91 | 121 | 151 | 181 | 211 | ||
| 20 | 10 | OUT | 628 | 126 | 188 | 251 | 314 | 377 | 440 |
| IN | 471 | 94 | 141 | 188 | 236 | 283 | 330 | ||
| 25 | 12 | OUT | 982 | 196 | 295 | 393 | 491 | 589 | 687 |
| IN | 756 | 151 | 227 | 302 | 378 | 454 | 529 | ||
Note) Theoretical output (N) = Pressure (MPa) x Pressure receiving area (mm2).