Individual Wiring Manifold M4KB1/2/3/4 Series Solenoid Valve Single Unit

Individual Wiring Manifold M4KB1/2/3/4 Series Solenoid Valve Single Unit

Compact valve with a wide lineup. Note: CAD data of this series is being revised. Please wait till the corrections are done.

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Part Number
4KB119-[00CE,​00Y,​00]-[AC100V,​AC110V,​AC200V,​AC220V,​DC12V,​DC24V]
4KB119-[00CE,​00Y,​00]-[AC100V,​AC110V,​AC200V,​AC220V,​DC12V,​DC24V]-P6
4KB119-[00CE,​00Y,​00]-M1-[AC100V,​AC110V,​AC200V,​AC220V,​DC12V,​DC24V]
4KB119-[00CE,​00Y,​00]-M1-[AC100V,​AC110V,​AC200V,​AC220V,​DC12V,​DC24V]-P6
4KB129-[00CE,​00Y,​00]-[AC100V,​AC110V,​AC200V,​AC220V,​DC12V,​DC24V]
4KB129-[00CE,​00Y,​00]-[AC100V,​AC110V,​AC200V,​AC220V,​DC12V,​DC24V]-P6
4KB129-[00CE,​00Y,​00]-M1-[AC100V,​AC110V,​AC200V,​AC220V,​DC12V,​DC24V]
4KB129-[00CE,​00Y,​00]-M1-[AC100V,​AC110V,​AC200V,​AC220V,​DC12V,​DC24V]-P6
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipSpecifications Number of Solenoids Status at Power Off Voltage Manual Equipment Connection Dia. copper ion generation prevention

-

1 Piece(s) 12 Day(s) or more StandardSingle[Self-Recovery (Spring Return)] Self-reset(differential pressure spring return)DC12V / DC24V / AC100V / AC110V / AC200V / AC220VNon-LockingBack Piping for Single Valve for Base Mounting / CE Type for Single Valve for Base Mounting / For single valve for base mounting-

-

1 Piece(s) 12 Day(s) or more -Single[Self-Recovery (Spring Return)] Self-reset(differential pressure spring return)DC12V / DC24V / AC100V / AC110V / AC200V / AC220VNon-LockingBack Piping for Single Valve for Base Mounting / CE Type for Single Valve for Base Mounting / For single valve for base mountingNon-Purple Specification

-

1 Piece(s) 12 Day(s) or more StandardSingle[Self-Recovery (Spring Return)] Self-reset(differential pressure spring return)DC12V / DC24V / AC100V / AC110V / AC200V / AC220VLockBack Piping for Single Valve for Base Mounting / CE Type for Single Valve for Base Mounting / For single valve for base mounting-

-

1 Piece(s) 12 Day(s) or more -Single[Self-Recovery (Spring Return)] Self-reset(differential pressure spring return)DC12V / DC24V / AC100V / AC110V / AC200V / AC220VLockBack Piping for Single Valve for Base Mounting / CE Type for Single Valve for Base Mounting / For single valve for base mountingNon-Purple Specification

-

1 Piece(s) 12 Day(s) or more StandardDoubleSelf-holdingDC12V / DC24V / AC100V / AC110V / AC200V / AC220VNon-LockingBack Piping for Single Valve for Base Mounting / CE Type for Single Valve for Base Mounting / For single valve for base mounting-

-

1 Piece(s) 12 Day(s) or more -DoubleSelf-holdingDC12V / DC24V / AC100V / AC110V / AC200V / AC220VNon-LockingBack Piping for Single Valve for Base Mounting / CE Type for Single Valve for Base Mounting / For single valve for base mountingNon-Purple Specification

-

1 Piece(s) 12 Day(s) or more StandardDoubleSelf-holdingDC12V / DC24V / AC100V / AC110V / AC200V / AC220VLockBack Piping for Single Valve for Base Mounting / CE Type for Single Valve for Base Mounting / For single valve for base mounting-

-

1 Piece(s) 12 Day(s) or more -DoubleSelf-holdingDC12V / DC24V / AC100V / AC110V / AC200V / AC220VLockBack Piping for Single Valve for Base Mounting / CE Type for Single Valve for Base Mounting / For single valve for base mountingNon-Purple Specification

Loading...

  1. 1

Basic Information

Type Electromagnetic Valve Application Unit for manifold Number of Ports 5-port valve
Mounting Orientation Manifold Base Switching Type 2-position exhaust Applicable Cylinder Dia.(Ø) 20 to 40
Plumbing Subbase Plumbing Driving Type Pilot-operated Spool Seal Type Soft seal