Control Unit Standard Solenoid Valve F15 Series

Caution
- [Discontinued Information]Part number: KOG1F15T2 will be discontinued in April 2022.
- When using the valve alone, select the option "Valve form symbol."
Please check the catalog for details of options.
Product Description
A pneumatic solenoid valve that has been further enhanced by the thorough pursuit of ease of use.
[Features]
·Supports cylinder diameters of 40 to 80 mm, valve width of 15 mm, and low power consumption
·Providing a new form of solenoid valve with a wide range of variations such as single/double types and reducer fittings
[Application]
・ Compatible with pneumatic equipment and production lines in all industries
Drawing

F15T valve specifications - Drawing of F3 - PS
unit: mm

F15T valve specifications - Drawing of F4 - PS
unit: mm
Product Specifications
Basic form and valve function
A new form of solenoid valve with a wide range of variations
| Item | Basic part number | |||
|---|---|---|---|---|
| F15□T0 | F15□T1 F15□T2 | F15□T3 F15□T4 F15□T5 | F15□TA F15□TB F15□TC | |
| Number of positions | 2 Positions | 3 position | 4 Position Type | |
| Number of ports | 5 | Tandem 3 port | ||
| Valve Functions | For Single Solenoid | Single solenoid, double solenoid dual-purpose type | Closed center, exhaust center, pressure center | NC/NC, NO/NO, NC/NO |
Product Specifications
| Item | Basic part number | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| F15□ T0F15□ T1F15□ T2 | F15□ T3F15□ T4F15□ T5 | F15□ TAF15□ TBF15□ TC | F15□ T0GF15□ T1GF15□ T2G | F15□ T3GF15□ T4GF15□ T5G | F15□ T0VF15□ T1VF15□ T2V | F15□T3V | |||
| Operating fluid | Air | ||||||||
| Operating method | Internal Pilot Type | External Pilot Type (for original pressure) | External pilot type (For vacuum) | ||||||
| Flow rate | Sonic conductance C dm^3 / (s*bar) | 2.05 | 2.05 | 1.6 | 2.05 | 2.05 | 2.05 | 2.05 | |
| Characteristic | Effective cross-sectional area [Cv value] mm^2 | 10.3 [0.57] | 10.3 [0.57] | 8 [0.44] | 10.3 [0.57] | 10.3 [0.57] | 10.3 [0.57] | 10.3 [0.57] | |
| Piping connection port diameter | ø6, ø8 dual-use fitting, Rc1/8 | M5 × 0.8, ø6, ø8 dual-use fitting, Rc1/8 | |||||||
| Lubrication | Not required | ||||||||
| Operating pressure range | Main valve | 0.15 to 0.7 MPa | 0 to 0.7 MPa | -100 kPa to 0.15 MPa | |||||
| External pilot | — | 0.2 to 0.7 MPa | 0.2 to 0.7 MPa | ||||||
| Proof pressure resistant MPa | 1.05 | ||||||||
| Response time | ms | 12 V DC, 24 V DC | 20/25 (30) or less | 15/45 (50) or less | 20/30 (35) or less | 20/25 (30) or less | 15/45 (50) or less | 20/25 (30) or less | 15/45 (50) or less |
| When ON/OFF | 100 V AC | 20/25 or less | 15/45 or less | — | 20/25 or less | 15/45 or less | 20/25 or less | 15/45 or less | |
| Maximum operating frequency: Hz | 5 | ||||||||
| Minimum excitation time required for self-holding ms | 50 | — | 50 | — | 50 | — | |||
| Operating temperature range (atmosphere and operating fluid)°C | 5 to 50 | ||||||||
| Impact resistance m/s^2 | 294.2 | ||||||||
| Mounting Direction | Free | ||||||||
Product Specifications
| Item | Rated Voltage | ||||||
|---|---|---|---|---|---|---|---|
| 12 V DC | 24 V DC (Standard type) | 24 V DC (Low current type) | 100 V AC | ||||
| Operating Voltage Range: V | 10.8 to 13.2 (12±10%) | 21.6 to 26.4 (24±10%) | 21.6 to 26.4 (24±10%) | 90 to 110 (100±10%) | |||
| Rated frequency Hz | — | — | — | 50 | 60 | ||
| Standard | Current value (When rated voltage is applied): mA (r.m.s) | 33 | 17 | — | 8 | ||
| Power consumption W | 0.4 | 0.4 | — | 0.8VA | |||
| Low-Current Type | Current (When rated voltage is applied) | Starting mA | — | — | 17 | — | |
| Constant mA | 4.2 | ||||||
| Power consumption | Starting mA | — | — | 0.4 | — | ||
| Constant mA | 0.1 | ||||||
| Startup time (standard time) ms | — | — | 70 | — | |||
| Allowable Circuit Leakage Current: mA | 2.0 | 1.0 | 1.0 | 1.0 | |||
| Insulation Type | Type B | ||||||
| Insulation resistance MΩ | 100 or More | ||||||
| Led Indicator Color | 14 (SA): Red, 12 (SB): Green | ||||||
| Surge Protection (Standard Equipment) | Surge absorption transistor | Flywheel diode | Bridge diode | ||||
Example of use

Single solenoid status

Double solenoid status

Example: ø6 (6 mm in diameter) tube connected

Example: ø4 (4 mm in diameter) tube connected
Secret story of development
It is a product with combining design know-how and production technology cultivated since the manufacturer founding to meet customer needs, and it is developed after undergoing strict inspection.