(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 21/4/2024 to 6:00 (SGT) 22/4/2024. We apologize for the inconvenience.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

Contact Probes(Receptacle Outermost Dia. D (Range):1.51~2)

Days to Ship
  • All
  • Same day
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 19 Day(s) or Less
  1. 1
Brand
Product Series
CAD
Days to Ship
Plunger Outer Dia. D1(Ø)
Mounting Pitch(mm)
Type
Allowable Current(A)
Plunger Length L1 (Range)(mm)
End Shape
Barrel, Receptacle Outer Dia. D2(Ø)
Barrel, Receptacle Length L2 (Range)(mm)
Integrated Probe Type
Plunger Surface Treatment
Receptacle Outermost Dia. D (Range)(Ø)
Properties
Plunger Material
Resistance(mΩ)
Plunger Tip Shape
Stroke (Range)(mm)
2/3 Stroke Spring Pressure (Range)(gf)
Barrel, Receptacle Material
Initial Spring Pressure (Range)(gf)

    Contact Probes and Receptacles-60 Series

      Turn Probes and Receptacles for Turn Probes

        Contact Probes and Receptacles-604 Series

          Contact Probes and Receptacles-120 Series

            Contact Probes and Receptacles-NPT1 Series/NRT1 Series

              Double Tipped Probes-NRB604 Series/NRB60 Series/C-Value

                Contact Probe / Receptacle (High Spring Pressure), 100 Series

                  Contact Probes and Receptacles-NPT2 Series/NRT2 Series

                    Receptacles with Lead Wire-NRB60/NRB120/NRB604 Series

                    Brand

                    MISUMI

                    MISUMI

                    MISUMI

                    MISUMI

                    MISUMI

                    MISUMI

                    MISUMI

                    MISUMI

                    MISUMI

                    Product Series

                    Contact Probes and Receptacles-60 Series

                    Turn Probes and Receptacles for Turn Probes

                    Contact Probes and Receptacles-604 Series

                    Contact Probes and Receptacles-120 Series

                    Contact Probes and Receptacles-NPT1 Series/NRT1 Series【50 Pieces Per Package】

                    Double Tipped Probes-NRB604 Series/NRB60 Series/C-Value

                    Contact Probe / Receptacle (High Spring Pressure), 100 Series【50 Pieces Per Package】

                    Contact Probes and Receptacles-NPT2 Series/NRT2 Series【50 Pieces Per Package】

                    Receptacles with Lead Wire-NRB60/NRB120/NRB604 Series

                    CAD
                    • 2D / 3D
                    • 2D / 3D
                    • 2D / 3D
                    • 2D / 3D
                    • 2D / 3D
                    • 2D / 3D
                    • 2D / 3D
                    • 2D / 3D
                    • 2D / 3D
                    Days to Ship Same day Same day Same day or more Same day Same day 5 Day(s) or more Same day Same day Same day or more
                    Plunger Outer Dia. D1(Ø)---------
                    Mounting Pitch(mm)---------
                    TypeReceptacleReceptacleReceptacleReceptacleReceptacleReceptacleReceptacleReceptacleReceptacle
                    Allowable Current(A)---------
                    Plunger Length L1 (Range)(mm)---------
                    End ShapeCylinder / Half Cylinder / Wire WrapCylinder / Half Cylinder / Wire WrapCylinder / Half Cylinder / Wire WrapCylinder-Half Cylinder---
                    Barrel, Receptacle Outer Dia. D2(Ø)1.681.681.681.45 ~ 1.61.431.681.661.671.45
                    Barrel, Receptacle Length L2 (Range)(mm)25.1~3025.1~3020.1~2525.1~30 / 30.1~15.1~2020.1~25 / 25.1~3025.1~3020.1~2525.1~30
                    Integrated Probe Type---------
                    Plunger Surface TreatmentNickel Plating Base, Gold PlatingNickel Plating Base, Gold PlatingNickel Plating Base, Gold PlatingNickel Plating Base, Gold Plating-Nickel Plating Base, Gold Plating--Nickel Plating Base, Gold Plating
                    Receptacle Outermost Dia. D (Range)(Ø)1.51~21.51~21.51~21.51~21.51~21.51~21.51~21.51~21.51~2
                    PropertiesStandardStandardStandardStandardStandardStandardStandardStandardStandard
                    Plunger Material---------
                    Resistance(mΩ)---------
                    Plunger Tip Shape---------
                    Stroke (Range)(mm)---------
                    2/3 Stroke Spring Pressure (Range)(gf)---------
                    Barrel, Receptacle MaterialCopper AlloyCopper AlloyCopper AlloyCopper Alloy-Copper Alloy--Copper Alloy
                    Initial Spring Pressure (Range)(gf)---------

                    Loading...

                    1. 1

                    Related Categories to Contact Probes