(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 21/4/2024 to 6:00 (SGT) 22/4/2024. We apologize for the inconvenience.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

Power relay G2RL

Power relay G2RL

A low-profile power relay with a height of just 15.7 mm, enabling it to be incorporated into small-sized equipment.
[Features]
· 1-pole, 2-pole and high-capacity types are available.
· High sensitivity with a power consumption of 400 mW.
· A highly insulated type with an impact withstand voltage of 10 kV and a minimum 8 mm insulation distance between the coil and contacts.
· Ambient operating temperature of -40 to 85°C.
· Complies with VDE standards as standard.
[Applications]
· For PCBs used in communications equipment, OA equipment, testing instruments, disaster/crime-prevention devices, security devices, etc.

PDF

Power Relay G2RL Specifications

Power Relay G2RL: related images

G2RL external appearance

Power Relay G2RL: related images

G2RL-1 composition

Power Relay G2RL: related images

G2RL-1 dimensional drawing, Units: mm
*Average dimensions.

Power Relay G2RL: related images

G2RL-1 PCB processing dimensional drawing

Power Relay G2RL: related images

G2RL-1 terminal layout/schematics
There is no coil polarity.

Power Relay G2RL: related images

G2RL-1A-E composition

Power Relay G2RL: related images

G2RL-1A-E dimensional drawing, Units: mm
*Average dimensions.

Power Relay G2RL: related images

G2RL-1A-E PCB processing dimensional drawing

Power Relay G2RL: related images

G2RL-1A-E terminal layout/schematics
There is no coil polarity.

Power Relay G2RL: related images

Reference data: Ambient temperature and maximum allowable voltage
Note: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.

ClassificationStandard TypeHigh Capacity Type
Number of Contacts1 Pole2 Pole1 Pole
ItemsContact Resistance *1100 mΩ or Less
Turn-ON Time15 ms or Less
Turn-OFF Time5 ms or Less
Maximum Switching FrequencyMechanical18,000 Times/h
Rated Load1,800 Times/h
Insulation Resistance *21,000 MΩ or More
Withstand VoltageBetween Coil and Contact5,000 V AC 50/60 Hz 1 min
Between Contacts of Same Polarity1,000 V AC 50/60 Hz 1 min
Between Contacts of Different Polarities-2,500 V AC 50/60 Hz 1 min-
Insulation DistanceBetween Coil and ContactSpace: 8 mm, Creepage: 8 mm
Impulse Withstand Voltage10 kV (1.2 × 50 μs)
VibrationDurability10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude 1.5 mm)
Malfunction10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude 1.5 mm)
Shock / ImpactDurability1,000 m/s2
MalfunctionEnergized: 100 m/s2, Non-Energized: 100 m/s2
DurabilityMechanical20,000,000 Times or More (Switching Frequency: 18,000 Times/h)
Electrical *3
(Resistance Load)
Model: G2RL-1A
: 250 V AC 10 A, 100,000 Times
: 24 V DC 10 A, 30,000 Times
Model G2RL-1
: 250 V AC 10 A, 50,000 Times
: 24 V DC 10 A, 30,000 Times
Model: G2RL-2A
: 250 V AC 5 A, 100,000 Times
: 24 V DC 5 A, 30,000 Times
Model G2RL-2
: 250 V AC 5 A, 50,000 Times
: 24 V DC 5 A, 30,000 Times
Model: G2RL-1A-E(-ASI)
: 250 V AC 16 A, 50,000 Times
: 24 V DC 16 A, 30,000 Times
Model G2RL-1-E
: 250 V AC 16 A, 30,000 Times
: 24 V DC 16 A, 30,000 Times
Ambient Operating Temperature-40 to +85°C (Assuming No Freezing or Condensation)
Operating Ambient Humidity5 to 85% RH
WeightApprox. 12 g

Note: The above values are the initial default values.

  • *1. Measurement conditions: 5 V DC 1 A, voltage drop method.
  • *2. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter.
  • *3 Switching frequency: 1,800 Times/h
  • *Refer to the catalog for specifications other than those above.
Part Number
G2RL-1 DC12
G2RL-1 DC24
G2RL-1-E DC12
G2RL-1-E DC24
G2RL-1A-E DC24
G2RL-2 DC5
G2RL-2 DC12
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipContact Configuration Contact rated current (minimum value for AC and DC)
(A)
Coil rated voltage (DC)
(V)
Classification Note

SGD 6.37

1 Piece(s) Same day 1c1012Standard Type-

SGD 6.37

1 Piece(s) Same day 1c1024Standard Type-

SGD 7.28

1 Piece(s) Same day 1c1612High Capacity TypeHigh Capacity Type

SGD 6.36

1 Piece(s) Same day 1c1624Standard TypeHigh Capacity Type

SGD 7.13

1 Piece(s) Same day 1a1624High Capacity Type-

SGD 5.10

1 Piece(s) Same day 2c55Standard Type-

SGD 5.10

1 Piece(s) Same day 2c512Standard Type-

Loading...

  1. 1
 

Basic Information

Application Power Latch function NA Terminal shape For Circuit Boards
Representative Standard UL / CSA Dimension height(mm) 15.7 Dimension width(mm) 29
Dimension depth(mm) 12.7 Contact mechanism Single Protective Structure Flux resistant shape

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)