UL2464FASB UL Standard with Shield

UL2464FASB UL Standard with Shield

Click this image to zoom it.

Move the mouse over the image to zoom

300 V UL Mobile Signals Cable with Shield

  • VW-1
  • ULAWM
  • Strand Wire
  • Thinned Wire Conductor
  • Single Shield
  • Twisted Pair
  • 300 V

● It uses a copper foil shield for excellent shield bending performance.

· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)

Electrical Appliance and Material Safety Law certificate has not been obtained.

PDF

Part Number

Configured Part Number is shown.

UL2464FASB-23-8-[1-100/1]

Specifications

UL2464FASB UL Standard with Shield:Related Image
* Though the number of cores is marked, all sizes feature twisted pair stranding.
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model NumberAWG SizeCore Number (Pair Number) * 3Total Length
or
Specified Length
UL2464FASB252 (1P)1
~
100
(Specify 1 m
Increment)
4 (2P)
6 (3P)
8 (4P)
10 (5P)
12 (6P)
16 (8P)
20 (10P)
232 (1P)
4 (2P)
6 (3P)
8 (4P)
10 (5P)
12 (6P)
16 (8P)
20 (10P)
202 (1P)
4 (2P)
6 (3P)
8 (4P)
10 (5P)


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
* 1 Stock products are indicated with T or A in the price column at right.
* 2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* 3 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering.

More Information

UL2464FASB UL Standard with Shield:Related ImageUL2464FASB UL Standard with Shield:Related Image

UL2464FASB UL Standard with Shield:Related Image
UL2464FASB UL Standard with Shield:Related Image
UL2464FASB UL Standard with Shield:Related Image

Specifications

Model NumberAWG
Size
Number of CoresEstimated
Section Area
( mm2) *1
Twisted
Structure
(See Figure)
Pair Core
Number of Wires
Finished *5
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided *4
Allowable Current
A (30°C) *2
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *3Thickness
(mm)
Material *3Thickness
(mm)
Material *3
UL2464FASB2520.2Twisted Pair2 (1P)4.7263.58105 or less1000
or more
200040/0.080.58Tin0.2Fluorine (ETFE)0.981.0PVCULAWM2464-
44 (2P)6.3442.77-
66 (3P)6.6502.34-
88 (4P)7.1602.05-
1010 (5P)7.6701.91-
1212 (6P)8751.62-
1616 (8P)9.11001.43-
2020 (10P)10.21201.43-
2320.32 (1P)5304.769.5 or less60/0.080.720.21.12-
44 (2P)6.9513.63-
66 (3P)7.2603.07-
88 (4P)7.7712.69-
1010 (5P)8.3852.5-
1212 (6P)8.8952.13-
1616 (8P)10.11251.88-
2020 (10P)11.31501.88-
2020.52 (1P)5.5516.9740.1 or less104/0.080.940.251.44-
44 (2P)8755.39-
66 (3P)8.5954.55-
88 (4P)9.21154-
1010 (5P)9.91353.72-


*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above. 
 
Current Reduction Factor
Ambient Temperature (°C)3040506070
Current Reduction Factor1.000.900.780.640.45
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 3.58 x 0.90 = 3.222 (A) when the ambient temperature for 2-core AWG25 is 40 °C

Part Number
UL2464FASB-23-8-[1-100/1]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)

-

1 Piece(s) 4 Day(s) or more 1 ~ 100

Loading...

  1. 1

Basic Information

Conductor Cross Section(mm2) 0.3 AWG size(AWG) 23 Number Of Cores(Core) 8
Logarithm 4 Finished outer diameter(mm) 7.7 Rated Voltage 300V
Shield Present Representative Standard UL Sheath (outer coating) color Black
Sheath (outer coating) material PVC Insulation body materials Fluorine Other properties Elastic, Vibration-resistant