(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 21/4/2024 to 6:00 (SGT) 22/4/2024. We apologize for the inconvenience.
  • Please Note our New Address (effective April 1, 2024): 331 North Bridge Rd, #05-01 Odeon 331, Singapore 188720.

MRC6 (SB) UL Standard

MRC6 (SB) UL Standard

Click this image to zoom it.

Move the mouse over the image to zoom

  • MRC6 (SB) UL Standard
  • MRC6 (SB) UL Standard

600 V UL / CSA Mobile Power Supply Cable

  • CSA
  • VW-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Thinned Wire Conductor
  • 600 V


● Available in both shielded model and non-shielded model.

· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)

The Electrical Appliance and Material Safety Law certificate has not been obtained.

PDF

Part Number

Configured Part Number is shown.

Specifications

MRC6 (SB) UL Standard:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model Number AWG Size Number of Cores Total Length
or
Specified Length
MRC6
(Without Shield)
AWG18 2 1
~
100
(Specify 1 m
Increment)
3
4
6
AWG16 2
3
4
6
MRC6SB
(With Shield)
AWG18 2
3
4
6
AWG16 2
3
4
6



Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
*1 All unit prices above are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
*2 The size conversion is for reference only. Refer to the comparison table on >>P.1688 for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other

More Information

MRC6 (SB) UL Standard:Related Image
MRC6 (SB) UL Standard:Related Image

MRC6 (SB) UL Standard:Related Image
MRC6 (SB) UL Standard:Related Image

MRC6 (SB) UL Standard:Related Image
MRC6 (SB) UL Standard:Related Image

Specifications

Model Number AWG
Size
Number of Cores Estimated
Section Area
( mm2) *2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification
Allowable Current
A (30°C) *3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4 Thickness
(mm)
Material *4 Thickness
(mm)
Material *4
MRC6
(Without Shield)
AWG18 2 0.75 Core / Layer
Stranding
2 9.5 104 13 25.3 or less 50 or more 2000 6/28/0.08 1.3 N/A 0.85 PVC 3 1.7 PVC ULAWM
2501
CSA
3 3 10 124 11
4 4 10.7 150 10
6 6 12.5 201 9
AWG16 2 1.25 2 10.3 126 17 16.1 or less 6/44/0.08 1.7 3.4
3 3 10.8 153 14
4 4 11.7 188 13
6 6 13.7 253 11
MRC6SB
(With Shield)
AWG18 2 0.75 2 10.1 125 13 26.1 or less 6/28/0.08 1.3 3
3 3 10.6 147 11
4 4 11.4 180 10
6 6 13.2 240 9
AWG16 2 1.25 2 10.9 150 17 16.6 or less 6/44/0.08 1.7 3.4
3 3 11.5 182 14
4 4 12.4 221 13
6 6 14.5 300 11


Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70 80 90 100
Current Reduction Factor 1.00 0.93 0.85 0.77 0.68 0.58 0.45 0.26

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 13 x 0.93 = 12.09 (A) when the ambient temperature for 2-core AWG18 is 40 °C

Part Number
MRC6-16-6-100
MRC6-18-6-100
MRC6SB-16-6-100
MRC6SB-18-3-100
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Finished outer diameter
(mm)
Shield Other properties

SGD 4,232.20

1 Piece(s) 4 Day(s) or more 1.2516613.7NoneVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

SGD 3,004.93

1 Piece(s) 4 Day(s) or more 0.7518612.5NoneVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

SGD 5,013.98

1 Piece(s) 4 Day(s) or more 1.2516614.5[Available] PresentVibration-resistant, Flexible, Pliable, Elastic, Noise-resistant, Carrier-tested Cable

SGD 2,429.74

1 Piece(s) 4 Day(s) or more 0.7518310.6[Available] PresentVibration-resistant, Flexible, Pliable, Elastic, Noise-resistant, Carrier-tested Cable

Loading...

  1. 1

Basic Information

Overall Length(m) 100 Rated Voltage 600V Properties Oil resistance
Representative Standard UL / CSA(c-UL) Sheath (outer coating) color Black Grounding Wire GY (green/yellow) colored
Sheath (outer coating) material PVC Insulation body materials PVC Power supply/signal Dual use

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)